Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,139
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0287 # 03 Y:2000 | 03 | 2000 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $501 | $240 | Implemented |
AS0287 # 04 Y:2000 | 04 | 2000 | INSTALL OCCUPANCY SENSORS | $4,295 | $4,875 | Not Implemented |
AS0287 # 05 Y:2000 | 05 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $572 | $2,394 | Not Implemented |
AS0287 # 06 Y:2000 | 06 | 2000 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $25,067 | $24,000 | Implemented |
AS0287 # 07 Y:2000 | 07 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $668 | $120 | Not Implemented |
AS0287 # 08 Y:2000 | 08 | 2000 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,700 | $60 | Not Implemented |
AS0287 # 09 Y:2000 | 09 | 2000 | ADOPT IN-HOUSE MATERIAL GENERATION | $37,832 | $100,000 | Not Implemented |
CO0474 # 01 Y:2000 | 01 | 2000 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $8,930 | $10,000 | Implemented |
CO0474 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,680 | $560 | Implemented |
CO0474 # 03 Y:2000 | 03 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,060 | $2,250 | Not Implemented |
CO0474 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $70 | $0 | Implemented |
CO0474 # 05 Y:2000 | 05 | 2000 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $329,200 | $60,000 | Implemented |
CO0474 # 06 Y:2000 | 06 | 2000 | PURCHASE RE-CONDITIONED MATERIAL INSTEAD OF NEW | $2,400 | $0 | Not Implemented |
MA0474 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,827 | $1,000 | Implemented |
MA0474 # 02 Y:2000 | 02 | 2000 | INSTALL TIMERS AND/OR THERMOSTATS | $4,760 | $0 | Implemented |
MA0474 # 03 Y:2000 | 03 | 2000 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $2,838 | $13,000 | Not Implemented |
MA0474 # 04 Y:2000 | 04 | 2000 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $746 | $4,000 | Not Implemented |
MA0474 # 05 Y:2000 | 05 | 2000 | INSTALL OCCUPANCY SENSORS | $512 | $1,000 | Implemented |
MA0474 # 06 Y:2000 | 06 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $371 | $100 | Implemented |
ND0364 # 01 Y:2000 | 01 | 2000 | DEVELOP A REPAIR/REPLACE POLICY | $8,340 | $22,377 | Implemented |
ND0364 # 02 Y:2000 | 02 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,206 | $0 | Implemented |
ND0364 # 03 Y:2000 | 03 | 2000 | INSTALL OCCUPANCY SENSORS | $839 | $600 | Not Implemented |
ND0364 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $271 | $575 | Implemented |
ND0364 # 05 Y:2000 | 05 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,221 | $1,000 | Not Implemented |
ND0364 # 06 Y:2000 | 06 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $75 | $200 | Implemented |