Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,139
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0247 # 03 Y:1999 | 03 | 1999 | INSTALL OCCUPANCY SENSORS | $587 | $1,275 | Implemented |
AS0247 # 04 Y:1999 | 04 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $226 | $253 | Implemented |
AS0247 # 05 Y:1999 | 05 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,734 | $4,593 | Not Implemented |
AS0247 # 06 Y:1999 | 06 | 1999 | USE EVAPORATION TO CONCENTRATE MATERIAL | $18,060 | $5,209 | Not Implemented |
AS0247 # 07 Y:1999 | 07 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $19,300 | $120 | Implemented |
AS0247 # 08 Y:1999 | 08 | 1999 | ADD ADDITIONAL PRODUCTION SHIFT | $25,200 | $24,000 | Implemented |
KU0512 # 01 Y:1999 | 01 | 1999 | USE IMMERSION HEATING IN TANKS, MELTING POTS, ETC | $30,880 | $31,230 | Not Implemented |
KU0512 # 02 Y:1999 | 02 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $17,150 | $28,520 | Not Implemented |
KU0512 # 03 Y:1999 | 03 | 1999 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $10,840 | $18,000 | Not Implemented |
KU0512 # 04 Y:1999 | 04 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,640 | $810 | Not Implemented |
KU0512 # 05 Y:1999 | 05 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,460 | $270 | Not Implemented |
KU0512 # 06 Y:1999 | 06 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,120 | $1,800 | Not Implemented |
KU0512 # 07 Y:1999 | 07 | 1999 | INSULATE BARE EQUIPMENT | $1,520 | $1,030 | Not Implemented |
KU0512 # 08 Y:1999 | 08 | 1999 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $990 | $700 | Not Implemented |
KU0512 # 09 Y:1999 | 09 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $550 | $770 | Not Implemented |
KU0512 # 10 Y:1999 | 10 | 1999 | CONVERT TO ELECTROSTATIC POWDER COATING | $278,220 | $513,480 | Not Implemented |
KU0512 # 11 Y:1999 | 11 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $800,000 | $29,240 | Not Implemented |
KU0512 # 12 Y:1999 | 12 | 1999 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $220,990 | $233,750 | Not Implemented |
OD0131 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $416 | $900 | Not Implemented |
OD0131 # 02 Y:1999 | 02 | 1999 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $4,051 | $3,290 | Not Implemented |
OD0131 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,972 | $800 | Not Implemented |
OD0131 # 04 Y:1999 | 04 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,202 | $0 | Not Implemented |
NV0124 # 01 Y:1999 | 01 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,858 | $7,243 | Implemented |
NV0124 # 02 Y:1999 | 02 | 1999 | INSULATE BARE EQUIPMENT | $1,150 | $800 | Not Implemented |
NV0124 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $292 | $135 | Not Implemented |