Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,208
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0578 # 08 Y:2021 | 08 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,673 | $46,439 | Implemented |
WM0169 # 01 Y:2021 | 01 | 2021 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,165 | $21,350 | Not Implemented |
WM0169 # 02 Y:2021 | 02 | 2021 | USE SYNTHETIC LUBRICANT | $4,530 | $3,000 | Not Implemented |
WM0169 # 03 Y:2021 | 03 | 2021 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,251 | $0 | Not Implemented |
WM0169 # 04 Y:2021 | 04 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,969 | $4,800 | Implemented |
WM0169 # 05 Y:2021 | 05 | 2021 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,662 | $8,830 | Not Implemented |
WM0169 # 06 Y:2021 | 06 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,352 | $2,425 | Implemented |
WM0169 # 07 Y:2021 | 07 | 2021 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $920 | $2,140 | Not Implemented |
SF0577 # 01 Y:2021 | 01 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,483 | $0 | Implemented |
SF0577 # 02 Y:2021 | 02 | 2021 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $141 | $62 | Implemented |
SF0577 # 03 Y:2021 | 03 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,636 | $26,920 | Implemented |
SF0577 # 04 Y:2021 | 04 | 2021 | UPGRADE CONTROLS ON COMPRESSORS | $4,632 | $30,160 | Implemented |
SF0577 # 05 Y:2021 | 05 | 2021 | USE SOLAR HEAT TO MAKE ELECTRICTY | $77,365 | $283,655 | Implemented |
DL0197 # 01 Y:2021 | 01 | 2021 | USE OPTIMUM TEMPERATURE | $8,560 | $0 | Not Implemented |
DL0197 # 02 Y:2021 | 02 | 2021 | ADD AREA LIGHTING SWITCHES | $21,520 | $846 | Not Implemented |
DL0197 # 03 Y:2021 | 03 | 2021 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $9,710 | $0 | Implemented |
DL0197 # 04 Y:2021 | 04 | 2021 | INSTALL TIMERS AND/OR THERMOSTATS | $730 | $135 | Implemented |
DL0197 # 05 Y:2021 | 05 | 2021 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $2,034 | $1,300 | Implemented |
DL0197 # 06 Y:2021 | 06 | 2021 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $12,960 | $173,544 | Implemented |
DL0197 # 07 Y:2021 | 07 | 2021 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,810 | $1,098 | Not Implemented |
DL0197 # 08 Y:2021 | 08 | 2021 | REPLACE BOILER | $8,560 | $23,609 | Not Implemented |
DL0197 # 09 Y:2021 | 09 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,313 | $39,529 | Implemented |
DL0197 # 10 Y:2021 | 10 | 2021 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $1,950 | $9,070 | Not Implemented |
DL0197 # 11 Y:2021 | 11 | 2021 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,320 | $14,125 | Not Implemented |
OK1059 # 01 Y:2022 | 01 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,353 | $8,612 | Implemented |