Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
436
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0286 # 09 Y:2004 | 09 | 2004 | INSTALL OCCUPANCY SENSORS | $247 | $191 | Implemented |
NC0286 # 10 Y:2004 | 10 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $61 | $70 | Not Implemented |
NC0268 # 01 Y:2003 | 01 | 2003 | AUTOMATE FINISHING PROCESS | $29,974 | $26,350 | Not Implemented |
NC0268 # 02 Y:2003 | 02 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $9,563 | $8,000 | Not Implemented |
NC0268 # 03 Y:2003 | 03 | 2003 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $10,491 | $2,000 | Not Implemented |
NC0268 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $693 | $500 | Implemented |
NC0268 # 05 Y:2003 | 05 | 2003 | INSULATE BARE EQUIPMENT | $162 | $329 | Not Implemented |
NC0268 # 06 Y:2003 | 06 | 2003 | USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER | $1,012 | $300 | Not Implemented |
NC0250 # 01 Y:2002 | 01 | 2002 | MAKE ICE DURING OFF PEAK HOURS FOR COOLING | $13,524 | $16,000 | n/a |
NC0250 # 02 Y:2002 | 02 | 2002 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $37,000 | $12,000 | n/a |
NC0250 # 03 Y:2002 | 03 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,259 | $20,000 | Not Implemented |
NC0250 # 04 Y:2002 | 04 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,244 | $12,245 | Not Implemented |
NC0250 # 05 Y:2002 | 05 | 2002 | AIR CONDITION ONLY SPACE NECESSARY | $65,851 | $10,750 | Not Implemented |
NC0250 # 06 Y:2002 | 06 | 2002 | INSTALL BACK-UP EQUIPMENT | $13,440 | $35,000 | Not Implemented |
NC0250 # 07 Y:2002 | 07 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $798 | $1,293 | Not Implemented |
NC0250 # 08 Y:2002 | 08 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $322 | $921 | Not Implemented |
NC0250 # 09 Y:2002 | 09 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,251 | $420 | Implemented |
NC0234 # 01 Y:2002 | 01 | 2002 | USE EVAPORATION TO CONCENTRATE MATERIAL | $47,833 | $90,000 | n/a |
NC0234 # 02 Y:2002 | 02 | 2002 | ADJUST BURNERS FOR EFFICIENT OPERATION | $744 | $800 | Implemented |
NC0234 # 03 Y:2002 | 03 | 2002 | INSULATE BARE EQUIPMENT | $1,927 | $500 | Implemented |
NC0234 # 04 Y:2002 | 04 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $199 | $289 | Implemented |
NC0212 # 01 Y:2001 | 01 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,685 | $25 | Implemented |
NC0212 # 02 Y:2001 | 02 | 2001 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $5,740 | $5,000 | Not Implemented |
NC0212 # 03 Y:2001 | 03 | 2001 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $2,554 | $11,000 | Not Implemented |
NC0212 # 04 Y:2001 | 04 | 2001 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $1,456 | $800 | Not Implemented |