Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
291
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0036 # 03 Y:2009 | 03 | 2009 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $15,005 | $15,600 | Not Implemented |
UA0036 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $29,387 | $40,768 | Implemented |
UA0036 # 05 Y:2009 | 05 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,452 | $10,320 | Not Implemented |
UA0036 # 06 Y:2009 | 06 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $912 | $1,500 | Implemented |
UA0036 # 07 Y:2009 | 07 | 2009 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $6,637 | $17,500 | Not Implemented |
UA0036 # 08 Y:2009 | 08 | 2009 | USE PHOTOCELL CONTROLS | $453 | $1,337 | Not Implemented |
UA0031 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,812 | $41,878 | Implemented |
UA0031 # 02 Y:2009 | 02 | 2009 | USE PHOTOCELL CONTROLS | $3,768 | $1,894 | Not Implemented |
UA0031 # 03 Y:2009 | 03 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $2,044 | $510 | Implemented |
UA0031 # 04 Y:2009 | 04 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,868 | $0 | Not Implemented |
UA0031 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,910 | $1,500 | Implemented |
UA0031 # 06 Y:2009 | 06 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $1,573 | $300 | Not Implemented |
UA0031 # 07 Y:2009 | 07 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,782 | $1,385 | Not Implemented |
UA0031 # 08 Y:2009 | 08 | 2009 | INSULATE BARE EQUIPMENT | $350 | $610 | Implemented |
UA0029 # 01 Y:2009 | 01 | 2009 | USE PHOTOCELL CONTROLS | $41 | $109 | Not Implemented |
UA0029 # 02 Y:2009 | 02 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $650 | $1,416 | Implemented |
UA0029 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,785 | $14,634 | Implemented |
UA0029 # 04 Y:2009 | 04 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,679 | $2,900 | Not Implemented |
UA0029 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,613 | $1,500 | Not Implemented |
UA0029 # 06 Y:2009 | 06 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,679 | $0 | Implemented |
UA0029 # 07 Y:2009 | 07 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,902 | $17,383 | Implemented |
UA0029 # 08 Y:2009 | 08 | 2009 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $7,112 | $109 | Not Implemented |
UA0009 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,681 | $16,061 | Implemented |
UA0009 # 02 Y:2007 | 02 | 2007 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $588 | $0 | Implemented |
UA0009 # 03 Y:2007 | 03 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $234 | $10 | Not Implemented |