Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

487

matching recommendations
Reset
SIC 34 Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0428 # 05 Y:2013 05 2013 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,177 $9,000 Implemented
UM0428 # 06 Y:2013 06 2013 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $1,332 $500 Not Implemented
CO0670 # 01 Y:2013 01 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,960 $670 Implemented
CO0670 # 02 Y:2013 02 2013 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,830 $25,400 Not Implemented
CO0670 # 03 Y:2013 03 2013 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $3,800 $620 Implemented
CO0670 # 04 Y:2013 04 2013 INSULATE BARE EQUIPMENT $1,160 $330 Implemented
CO0670 # 05 Y:2013 05 2013 USE EVAPORATION TO CONCENTRATE MATERIAL $660 $0 Implemented
CO0670 # 06 Y:2013 06 2013 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $6,080 $500 Implemented
SF0436 # 01 Y:2013 01 2013 COVER OPEN TANKS $6,314 $150 Not Implemented
SF0436 # 02 Y:2013 02 2013 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $438 $0 Implemented
SF0436 # 03 Y:2013 03 2013 UPGRADE CONTROLS ON COMPRESSORS $2,488 $3,272 Not Implemented
SF0436 # 04 Y:2013 04 2013 INSTALL OCCUPANCY SENSORS $864 $2,751 Not Implemented
SF0436 # 05 Y:2013 05 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,275 $12,405 Not Implemented
SF0436 # 06 Y:2013 06 2013 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $608 $2,400 Not Implemented
BD0430 # 01 Y:2013 01 2013 USE RADIANT HEATER FOR SPOT HEATING $7,450 $22,500 Not Implemented
BD0430 # 02 Y:2013 02 2013 USE PHOTOCELL CONTROLS $2,289 $200 Not Implemented
BD0430 # 03 Y:2013 03 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,001 $3,520 Not Implemented
BD0430 # 04 Y:2013 04 2013 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $741 $25 Not Implemented
BD0430 # 05 Y:2013 05 2013 INSTALL OCCUPANCY SENSORS $397 $200 Not Implemented
BD0430 # 06 Y:2013 06 2013 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $278 $600 Not Implemented
BD0430 # 07 Y:2013 07 2013 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL $4,500 $10,000 Implemented
UM0425 # 01 Y:2013 01 2013 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $9,900 $13,000 Not Implemented
UM0425 # 02 Y:2013 02 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,480 $3,300 Implemented
UM0425 # 03 Y:2013 03 2013 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,115 $0 Implemented
UM0425 # 04 Y:2013 04 2013 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $6,752 $5,000 Implemented