Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
803
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0655 # 06 Y:1998 | 06 | 1998 | CONVERT TO ELECTROSTATIC POWDER COATING | $7,580 | $4,800 | Not Implemented |
OK0562 # 05 Y:1998 | 05 | 1998 | INSTALL OCCUPANCY SENSORS | $360 | $532 | Implemented |
GT0655 # 07 Y:1998 | 07 | 1998 | CONVERT TO ELECTROSTATIC POWDER COATING | $4,410 | $5,400 | Not Implemented |
OK0562 # 02 Y:1998 | 02 | 1998 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,344 | $1,516 | Not Implemented |
OK0562 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $850 | $110 | Implemented |
OK0562 # 08 Y:1998 | 08 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,160 | $0 | Implemented |
GT0655 # 08 Y:1998 | 08 | 1998 | $3,500 | $0 | Not Implemented | |
OK0562 # 07 Y:1998 | 07 | 1998 | $7,200 | $288 | Implemented | |
OK0562 # 09 Y:1998 | 09 | 1998 | METER WASTE WATER | $233 | $0 | Implemented |
OK0562 # 01 Y:1998 | 01 | 1998 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $14,801 | $1,936 | Implemented |
GT0655 # 01 Y:1998 | 01 | 1998 | OPTIMIZE PLANT POWER FACTOR | $5,800 | $5,000 | Implemented |
OK0562 # 04 Y:1998 | 04 | 1998 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $526 | $242 | Not Implemented |
OK0562 # 06 Y:1998 | 06 | 1998 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $7,243 | $0 | Not Implemented |
GT0655 # 05 Y:1998 | 05 | 1998 | MINIMIZE WATER USAGE | $6,576 | $0 | Implemented |
GT0655 # 03 Y:1998 | 03 | 1998 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $1,582 | $3,116 | Not Implemented |
GT0655 # 04 Y:1998 | 04 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,677 | $4,550 | Implemented |
GT0655 # 02 Y:1998 | 02 | 1998 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $10,690 | $1,250 | Implemented |
OK0540 # 05 Y:1998 | 05 | 1998 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $1,226 | $5,610 | n/a |
OK0540 # 04 Y:1998 | 04 | 1998 | INSTALL OCCUPANCY SENSORS | $783 | $1,188 | n/a |
OK0540 # 06 Y:1998 | 06 | 1998 | $6,531 | $0 | n/a | |
OK0540 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,180 | $2,828 | n/a |
OK0540 # 03 Y:1998 | 03 | 1998 | OPTIMIZE PLANT POWER FACTOR | $2,129 | $0 | n/a |
OK0540 # 01 Y:1998 | 01 | 1998 | $5,006 | $9,000 | n/a | |
AM0335 # 01 Y:1998 | 01 | 1998 | $19,840 | $320 | Not Implemented | |
AM0335 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,790 | $250 | Implemented |