Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
29
matching recommendationsSIC | 341 | Metal Cans And Shipping Containers |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0094 # 08 Y:1997 | 08 | 1997 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $150,800 | $2,000 | Implemented |
BD0094 # 07 Y:1997 | 07 | 1997 | TREAT AND REUSE RINSE WATERS | $16,735 | $34,000 | Implemented |
BD0094 # 06 Y:1997 | 06 | 1997 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $192,343 | $16,000 | Implemented |
BD0094 # 05 Y:1997 | 05 | 1997 | INSTALL OCCUPANCY SENSORS | $898 | $1,050 | Not Implemented |
BD0094 # 04 Y:1997 | 04 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,560 | $4,430 | Implemented |
BD0094 # 03 Y:1997 | 03 | 1997 | INSULATE BARE EQUIPMENT | $4,842 | $8,668 | Implemented |
BD0094 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,630 | $5,699 | Not Implemented |
BD0094 # 01 Y:1997 | 01 | 1997 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,910 | $1,500 | Not Implemented |
BD0088 # 02 Y:1997 | 02 | 1997 | INSTALL OCCUPANCY SENSORS | $3,946 | $1,275 | Not Implemented |
BD0088 # 08 Y:1997 | 08 | 1997 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $551 | $290 | Not Implemented |
BD0088 # 07 Y:1997 | 07 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $24,305 | $1,900 | Not Implemented |
BD0088 # 06 Y:1997 | 06 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,229 | $2,249 | Not Implemented |
BD0088 # 05 Y:1997 | 05 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,299 | $2,750 | Not Implemented |
BD0088 # 04 Y:1997 | 04 | 1997 | INSULATE BARE EQUIPMENT | $1,892 | $3,999 | Not Implemented |
BD0088 # 03 Y:1997 | 03 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,452 | $500 | Not Implemented |
BD0088 # 01 Y:1997 | 01 | 1997 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $19,848 | $18,325 | Not Implemented |
BD0088 # 09 Y:1997 | 09 | 1997 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $4,211 | $0 | Not Implemented |
NV0080 # 03 Y:1997 | 03 | 1997 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,478 | $125 | Implemented |
NV0080 # 02 Y:1997 | 02 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $728 | $50 | Not Implemented |
NV0080 # 01 Y:1997 | 01 | 1997 | ELIMINATE COOLING OF PROCESS STREAMS WHICH SUBSEQUENTLY MUST BE HEATED AND VICE VERSA | $1,252 | $200 | Implemented |
NV0080 # 04 Y:1997 | 04 | 1997 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $729 | $100 | Implemented |
NV0080 # 05 Y:1997 | 05 | 1997 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $336 | $100 | Implemented |
NV0080 # 06 Y:1997 | 06 | 1997 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $14,966 | $7,500 | Implemented |
OK0526 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,291 | $3,370 | Implemented |
OK0526 # 02 Y:1997 | 02 | 1997 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $5,426 | $11,087 | Implemented |