Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
563
matching recommendationsSIC | 342 | Cutlery, Handtools, And Hardware |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0483 # 05 Y:2001 | 05 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,650 | $800 | Implemented |
MA0483 # 07 Y:2001 | 07 | 2001 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $570 | $2,500 | Implemented |
SF0210 # 02 Y:2001 | 02 | 2001 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,719 | $4,350 | Implemented |
SF0210 # 03 Y:2001 | 03 | 2001 | INSTALL OCCUPANCY SENSORS | $869 | $2,640 | Implemented |
SF0210 # 06 Y:2001 | 06 | 2001 | SELL USED PLATES TO AN ALUMINUM RECYCLER | $3,400 | $70 | Implemented |
MA0474 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,827 | $1,000 | Implemented |
MA0474 # 02 Y:2000 | 02 | 2000 | INSTALL TIMERS AND/OR THERMOSTATS | $4,760 | $0 | Implemented |
MA0474 # 05 Y:2000 | 05 | 2000 | INSTALL OCCUPANCY SENSORS | $512 | $1,000 | Implemented |
MA0474 # 06 Y:2000 | 06 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $371 | $100 | Implemented |
AR0193 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,115 | $30 | Implemented |
AR0193 # 03 Y:2000 | 03 | 2000 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $2,360 | $3,000 | Implemented |
AR0193 # 04 Y:2000 | 04 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $553 | $653 | Implemented |
AR0193 # 06 Y:2000 | 06 | 2000 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $21,302 | $8,000 | Implemented |
AR0193 # 07 Y:2000 | 07 | 2000 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $23,524 | $1,000 | Implemented |
AM0366 # 01 Y:2000 | 01 | 2000 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,672 | $7,000 | Implemented |
AM0366 # 04 Y:2000 | 04 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $2,110 | $150 | Implemented |
AM0366 # 05 Y:2000 | 05 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,515 | $710 | Implemented |
AM0366 # 06 Y:2000 | 06 | 2000 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $255 | $0 | Implemented |
SD0229 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,875 | $2,988 | Implemented |
SD0229 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,665 | $500 | Implemented |
SD0229 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,377 | $120 | Implemented |
UM0136 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,707 | $9,821 | Implemented |
UM0136 # 02 Y:1999 | 02 | 1999 | AIR CONDITION ONLY SPACE NECESSARY | $1,684 | $400 | Implemented |
KU0511 # 01 Y:1998 | 01 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $25,680 | $19,610 | Implemented |
KU0511 # 03 Y:1998 | 03 | 1998 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $3,080 | $3,040 | Implemented |