Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
16
matching recommendationsSIC | 343 | Plumbing And Heating, Except Electric |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0336 # 05 Y:2006 | 05 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $12,198 | $7,290 | Implemented |
NC0336 # 08 Y:2006 | 08 | 2006 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $18,883 | $20,000 | Implemented |
NC0336 # 09 Y:2006 | 09 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,535 | $100 | Implemented |
NC0212 # 01 Y:2001 | 01 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,685 | $25 | Implemented |
NC0156 # 03 Y:1999 | 03 | 1999 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $461,046 | $1,000,000 | Implemented |
NC0156 # 04 Y:1999 | 04 | 1999 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $65,000 | $80,000 | Implemented |
NC0146 # 01 Y:1998 | 01 | 1998 | COVER OPEN TANKS | $488 | $600 | Implemented |
NC0146 # 02 Y:1998 | 02 | 1998 | INSULATE BARE EQUIPMENT | $920 | $800 | Implemented |
NC0146 # 03 Y:1998 | 03 | 1998 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $409 | $1,480 | Implemented |
NC0146 # 04 Y:1998 | 04 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $178 | $200 | Implemented |
NC0146 # 05 Y:1998 | 05 | 1998 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $13,890 | $1,500 | Implemented |
NC0146 # 06 Y:1998 | 06 | 1998 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $2,431 | $0 | Implemented |
TN0288 # 03 Y:1986 | 03 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $881 | $120 | Implemented |
TN0288 # 04 Y:1986 | 04 | 1986 | INSTALL SET-BACK TIMERS | $534 | $0 | Implemented |
TN0288 # 05 Y:1986 | 05 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $537 | $236 | Implemented |
TN0288 # 06 Y:1986 | 06 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $223 | $600 | Implemented |