Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,509
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0028 # 04 Y:2002 | 04 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,051 | $8 | n/a |
MI0028 # 05 Y:2002 | 05 | 2002 | RECYCLE WHITE WATER | $5,465 | $601 | n/a |
MI0028 # 06 Y:2002 | 06 | 2002 | COVER OPEN TANKS | $149 | $48 | n/a |
LL0130 # 03 Y:2002 | 03 | 2002 | INSTALL SKYLIGHTS | $6,716 | $734 | Not Implemented |
LL0130 # 04 Y:2002 | 04 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,838 | $0 | Implemented |
LL0130 # 05 Y:2002 | 05 | 2002 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,728 | $621 | Implemented |
LL0130 # 06 Y:2002 | 06 | 2002 | USE PHOTOCELL CONTROLS | $680 | $230 | Not Implemented |
LL0130 # 07 Y:2002 | 07 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $600 | $0 | Implemented |
LL0130 # 08 Y:2002 | 08 | 2002 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $45,027 | $0 | Implemented |
LL0130 # 01 Y:2002 | 01 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,705 | $0 | Implemented |
LL0130 # 02 Y:2002 | 02 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,729 | $2,340 | Implemented |
MS0199 # 01 Y:2002 | 01 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,110 | $3,070 | Not Implemented |
MS0199 # 02 Y:2002 | 02 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,645 | $437 | Implemented |
MS0199 # 03 Y:2002 | 03 | 2002 | INSTALL TIMERS AND/OR THERMOSTATS | $740 | $827 | Implemented |
MS0199 # 04 Y:2002 | 04 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $534 | $242 | Not Implemented |
MS0199 # 05 Y:2002 | 05 | 2002 | BURN WASTE OIL FOR HEAT | $1,181 | $409 | Not Implemented |
MS0199 # 06 Y:2002 | 06 | 2002 | EXPAND OPERATIONS INTO UNUSED SPACE | $500,000 | $1,000,000 | Not Implemented |
OK0625 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,900 | $360 | Implemented |
OK0625 # 02 Y:2001 | 02 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,851 | $84 | Implemented |
OK0625 # 03 Y:2001 | 03 | 2001 | INSTALL OCCUPANCY SENSORS | $376 | $476 | Implemented |
OK0625 # 04 Y:2001 | 04 | 2001 | INSTALL SET-BACK TIMERS | $2,642 | $1,408 | Not Implemented |
OK0625 # 05 Y:2001 | 05 | 2001 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $868 | $230 | Implemented |
OK0625 # 06 Y:2001 | 06 | 2001 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $39,782 | $95,000 | Implemented |
OK0625 # 07 Y:2001 | 07 | 2001 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $53,200 | $30,400 | Implemented |
IC0021 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,966 | $41,300 | Not Implemented |