Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,493
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0280 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,615 | $7,198 | Implemented |
UF0280 # 03 Y:2001 | 03 | 2001 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $15,000 | $50 | Implemented |
UF0280 # 04 Y:2001 | 04 | 2001 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $11,751 | $25,263 | Not Implemented |
UF0280 # 05 Y:2001 | 05 | 2001 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $9,972 | $20,010 | Not Implemented |
UF0280 # 06 Y:2001 | 06 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,427 | $8,000 | Implemented |
UF0280 # 07 Y:2001 | 07 | 2001 | RECOVER AND REUSE WASTE MATERIAL | $1,867 | $534 | Not Implemented |
UF0280 # 08 Y:2001 | 08 | 2001 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $117,000 | $120,250 | Not Implemented |
UF0280 # 09 Y:2001 | 09 | 2001 | INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM | $14,321 | $4,612 | Implemented |
AS0305 # 01 Y:2001 | 01 | 2001 | INSTALL SKYLIGHTS | $8,175 | $16,112 | Not Implemented |
AS0305 # 02 Y:2001 | 02 | 2001 | INSTALL OCCUPANCY SENSORS | $155 | $225 | Not Implemented |
AS0305 # 03 Y:2001 | 03 | 2001 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,492 | $3,850 | Not Implemented |
AS0305 # 04 Y:2001 | 04 | 2001 | USE SYNTHETIC LUBRICANT | $592 | $277 | Not Implemented |
AS0305 # 05 Y:2001 | 05 | 2001 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $4,588 | $110 | Implemented |
AS0305 # 06 Y:2001 | 06 | 2001 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $14,000 | $1,360 | Implemented |
AS0305 # 07 Y:2001 | 07 | 2001 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $63,963 | $6,820 | Implemented |
AS0304 # 01 Y:2001 | 01 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $895 | $120 | Not Implemented |
AS0304 # 02 Y:2001 | 02 | 2001 | INSTALL SKYLIGHTS | $1,241 | $1,992 | Not Implemented |
AS0304 # 03 Y:2001 | 03 | 2001 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $764 | $2,484 | Not Implemented |
AS0304 # 04 Y:2001 | 04 | 2001 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $5,488 | $648 | Implemented |
AS0304 # 05 Y:2001 | 05 | 2001 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $64,704 | $8,580 | Implemented |
AS0304 # 06 Y:2001 | 06 | 2001 | AUTOMATE FINISHING PROCESS | $58,240 | $688 | Not Implemented |
AS0304 # 07 Y:2001 | 07 | 2001 | DEMOLISH OLD BUILDING TO REDUCE TAX AND INSURANCE BILLS | $29,680 | $438 | Not Implemented |
AS0304 # 08 Y:2001 | 08 | 2001 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $19,493 | $294 | Implemented |
AS0304 # 09 Y:2001 | 09 | 2001 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $16,000 | $3,940 | Implemented |
OK0620 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,592 | $615 | Implemented |