Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,509
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0305 # 02 Y:2001 | 02 | 2001 | INSTALL OCCUPANCY SENSORS | $155 | $225 | Not Implemented |
AS0305 # 03 Y:2001 | 03 | 2001 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,492 | $3,850 | Not Implemented |
AS0305 # 04 Y:2001 | 04 | 2001 | USE SYNTHETIC LUBRICANT | $592 | $277 | Not Implemented |
AS0305 # 05 Y:2001 | 05 | 2001 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $4,588 | $110 | Implemented |
AS0305 # 06 Y:2001 | 06 | 2001 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $14,000 | $1,360 | Implemented |
AS0305 # 07 Y:2001 | 07 | 2001 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $63,963 | $6,820 | Implemented |
AS0304 # 01 Y:2001 | 01 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $895 | $120 | Not Implemented |
AS0304 # 02 Y:2001 | 02 | 2001 | INSTALL SKYLIGHTS | $1,241 | $1,992 | Not Implemented |
AS0304 # 03 Y:2001 | 03 | 2001 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $764 | $2,484 | Not Implemented |
AS0304 # 04 Y:2001 | 04 | 2001 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $5,488 | $648 | Implemented |
AS0304 # 05 Y:2001 | 05 | 2001 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $64,704 | $8,580 | Implemented |
AS0304 # 06 Y:2001 | 06 | 2001 | AUTOMATE FINISHING PROCESS | $58,240 | $688 | Not Implemented |
AS0304 # 07 Y:2001 | 07 | 2001 | DEMOLISH OLD BUILDING TO REDUCE TAX AND INSURANCE BILLS | $29,680 | $438 | Not Implemented |
AS0304 # 08 Y:2001 | 08 | 2001 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $19,493 | $294 | Implemented |
AS0304 # 09 Y:2001 | 09 | 2001 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $16,000 | $3,940 | Implemented |
OK0620 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,592 | $615 | Implemented |
OK0620 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $238 | $1,470 | Implemented |
OK0620 # 03 Y:2001 | 03 | 2001 | INSTALL OCCUPANCY SENSORS | $129 | $240 | Not Implemented |
OK0620 # 04 Y:2001 | 04 | 2001 | REPAIR AND ELIMINATE STEAM LEAKS | $1,442 | $200 | Implemented |
OK0620 # 05 Y:2001 | 05 | 2001 | INSTALL SET-BACK TIMERS | $8,700 | $1,170 | Implemented |
OK0620 # 06 Y:2001 | 06 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,130 | $40 | Implemented |
OK0620 # 07 Y:2001 | 07 | 2001 | INCREASE USE OF AUTOMATION | $4,160 | $38,900 | Not Implemented |
UU0008 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,523 | $125 | Implemented |
UU0008 # 02 Y:2001 | 02 | 2001 | USE SYNTHETIC LUBRICANT | $423 | $400 | Implemented |
UU0008 # 03 Y:2001 | 03 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,204 | $460 | Implemented |