Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,509
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0128 # 01 Y:1999 | 01 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,071 | $1,700 | Not Implemented |
UM0128 # 02 Y:1999 | 02 | 1999 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $885 | $2,000 | Not Implemented |
UM0128 # 03 Y:1999 | 03 | 1999 | INSTALL OCCUPANCY SENSORS | $2,650 | $1,000 | Not Implemented |
UM0128 # 04 Y:1999 | 04 | 1999 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $1,800 | $0 | Not Implemented |
UM0128 # 05 Y:1999 | 05 | 1999 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $13,800 | $0 | Not Implemented |
UM0128 # 06 Y:1999 | 06 | 1999 | INSTALL AUTOMATIC PACKING EQUIPMENT | $47,700 | $20,000 | Not Implemented |
UM0128 # 07 Y:1999 | 07 | 1999 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $16,635 | $450 | Not Implemented |
GT0655 # 01 Y:1998 | 01 | 1998 | OPTIMIZE PLANT POWER FACTOR | $5,800 | $5,000 | Implemented |
GT0655 # 02 Y:1998 | 02 | 1998 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $10,690 | $1,250 | Implemented |
GT0655 # 03 Y:1998 | 03 | 1998 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $1,582 | $3,116 | Not Implemented |
GT0655 # 04 Y:1998 | 04 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,677 | $4,550 | Implemented |
GT0655 # 05 Y:1998 | 05 | 1998 | MINIMIZE WATER USAGE | $6,576 | $0 | Implemented |
GT0655 # 06 Y:1998 | 06 | 1998 | CONVERT TO ELECTROSTATIC POWDER COATING | $7,580 | $4,800 | Not Implemented |
GT0655 # 07 Y:1998 | 07 | 1998 | CONVERT TO ELECTROSTATIC POWDER COATING | $4,410 | $5,400 | Not Implemented |
GT0655 # 08 Y:1998 | 08 | 1998 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $3,500 | $0 | Not Implemented |
OK0540 # 01 Y:1998 | 01 | 1998 | MOVE PRODUCT USING MECHANICAL MEANS | $5,006 | $9,000 | n/a |
OK0540 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,180 | $2,828 | n/a |
OK0540 # 03 Y:1998 | 03 | 1998 | OPTIMIZE PLANT POWER FACTOR | $2,129 | $0 | n/a |
OK0540 # 04 Y:1998 | 04 | 1998 | INSTALL OCCUPANCY SENSORS | $783 | $1,188 | n/a |
OK0540 # 05 Y:1998 | 05 | 1998 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $1,226 | $5,610 | n/a |
OK0540 # 06 Y:1998 | 06 | 1998 | MOVE PRODUCT USING MECHANICAL MEANS | $6,531 | $0 | n/a |
AM0333 # 01 Y:1998 | 01 | 1998 | MODIFY STARTUP/SHUTDOWN TIMES | $17,100 | $0 | Not Implemented |
AM0333 # 02 Y:1998 | 02 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,300 | $120 | Implemented |
AM0333 # 03 Y:1998 | 03 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $450 | $0 | Not Implemented |
AM0333 # 04 Y:1998 | 04 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $290 | $370 | Not Implemented |