Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,509
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0063 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $232 | $480 | Implemented |
MZ0063 # 02 Y:2011 | 02 | 2011 | ADJUST VENTS TO MINIMIZE ENERGY USE | $1,007 | $240 | Implemented |
MZ0063 # 03 Y:2011 | 03 | 2011 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $886 | $3,000 | Implemented |
MZ0063 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,168 | $1,200 | Implemented |
MZ0063 # 05 Y:2011 | 05 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,660 | $50 | Not Implemented |
MZ0063 # 06 Y:2011 | 06 | 2011 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $1,235 | $2,700 | Implemented |
UD0831 # 01 Y:2011 | 01 | 2011 | USE SOLAR HEAT TO MAKE ELECTRICTY | $28,448 | $196,170 | Not Implemented |
UD0831 # 02 Y:2011 | 02 | 2011 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $7,067 | $25,796 | Not Implemented |
UD0831 # 03 Y:2011 | 03 | 2011 | INSTALL SPECTRAL REFLECTORS / DELAMP | $4,392 | $3,863 | Implemented |
UD0831 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $713 | $10,495 | Implemented |
UD0831 # 05 Y:2011 | 05 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,848 | $12,100 | Not Implemented |
UD0831 # 06 Y:2011 | 06 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $904 | $1,167 | Not Implemented |
UD0831 # 07 Y:2011 | 07 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $189 | $240 | Implemented |
UD0831 # 08 Y:2011 | 08 | 2011 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $137 | $25 | Implemented |
SD0431 # 01 Y:2011 | 01 | 2011 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $213 | $0 | Not Implemented |
SD0431 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,286 | $500 | Implemented |
SD0431 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $89 | $98 | Not Implemented |
SD0431 # 04 Y:2011 | 04 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $817 | $2,000 | Not Implemented |
SD0431 # 05 Y:2011 | 05 | 2011 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $4,310 | $10,000 | Not Implemented |
UD0827 # 01 Y:2010 | 01 | 2010 | INSTALL OCCUPANCY SENSORS | $207 | $585 | Not Implemented |
UD0827 # 02 Y:2010 | 02 | 2010 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $5,123 | $58,000 | Not Implemented |
UD0827 # 03 Y:2010 | 03 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,804 | $5,800 | Not Implemented |
UD0827 # 04 Y:2010 | 04 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,258 | $800 | Not Implemented |
UD0827 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $995 | $500 | Implemented |
UD0827 # 06 Y:2010 | 06 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $15,685 | $48,000 | Not Implemented |