Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
85
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UL2213 # 01 Y:2022 | 01 | 2022 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $11,500 | $0 | Not Implemented |
UL2213 # 02 Y:2022 | 02 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $700 | $562 | Implemented |
UL2213 # 07 Y:2022 | 07 | 2022 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,277 | $10,869 | Not Implemented |
UL2213 # 08 Y:2022 | 08 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $45,075 | $458,134 | Implemented |
UL2213 # 03 Y:2022 | 03 | 2022 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,339 | $0 | Not Implemented |
UL2213 # 06 Y:2022 | 06 | 2022 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $447 | $0 | Not Implemented |
UL2213 # 04 Y:2022 | 04 | 2022 | INSTALL OCCUPANCY SENSORS | $124 | $564 | Implemented |
UL2213 # 05 Y:2022 | 05 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,734 | $1,440 | Implemented |
UL2202 # 02 Y:2022 | 02 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,861 | $12,941 | Implemented |
UL2202 # 08 Y:2022 | 08 | 2022 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $6,941 | $0 | Implemented |
UL2202 # 07 Y:2022 | 07 | 2022 | DEVELOP A REPAIR/REPLACE POLICY | $495 | $4,750 | Not Implemented |
UL2202 # 03 Y:2022 | 03 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,677 | $0 | Implemented |
UL2202 # 04 Y:2022 | 04 | 2022 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $649 | $0 | Not Implemented |
UL2202 # 05 Y:2022 | 05 | 2022 | OPTIMIZE PLANT POWER FACTOR | $16,897 | $12,250 | Not Implemented |
UL2202 # 01 Y:2022 | 01 | 2022 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $23,158 | $0 | Implemented |
UL2202 # 06 Y:2022 | 06 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $50,126 | $1,220,427 | Not Implemented |
UK1806 # 13 Y:2018 | 13 | 2018 | USE PLASTIC PALLETS INSTEAD OF WOOD | $8,000 | $18,890 | n/a |
UK1806 # 09 Y:2018 | 09 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,069 | $4,175 | n/a |
UK1806 # 01 Y:2018 | 01 | 2018 | UPGRADE CONTROLS ON COMPRESSORS | $10,567 | $9,500 | n/a |
UK1806 # 12 Y:2018 | 12 | 2018 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,467 | $0 | n/a |
UK1806 # 03 Y:2018 | 03 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,312 | $1,100 | n/a |
UK1806 # 04 Y:2018 | 04 | 2018 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $17,440 | $18,575 | n/a |
UK1806 # 05 Y:2018 | 05 | 2018 | USE RADIANT HEATER FOR SPOT HEATING | $14,227 | $14,700 | n/a |
UK1806 # 06 Y:2018 | 06 | 2018 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $456 | $0 | n/a |
UK1806 # 08 Y:2018 | 08 | 2018 | USE PHOTOCELL CONTROLS | $1,514 | $2,900 | n/a |