Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
591
matching recommendationsSIC | 3443 | Fabricated Plate Work (boiler Shops) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0360 # 06 Y:1999 | 06 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $420 | $200 | Implemented |
AM0360 # 07 Y:1999 | 07 | 1999 | INSTALL OCCUPANCY SENSORS | $190 | $110 | Implemented |
AM0360 # 08 Y:1999 | 08 | 1999 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $100 | $0 | Implemented |
MO0264 # 03 Y:1999 | 03 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $949 | $1,518 | Implemented |
MO0264 # 04 Y:1999 | 04 | 1999 | INSULATE BARE EQUIPMENT | $960 | $300 | Implemented |
MO0264 # 05 Y:1999 | 05 | 1999 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,600 | $0 | Implemented |
KU0522 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,170 | $710 | Implemented |
KU0522 # 03 Y:1999 | 03 | 1999 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $470 | $0 | Implemented |
KU0522 # 05 Y:1999 | 05 | 1999 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $7,710 | $1,100 | Implemented |
KU0522 # 06 Y:1999 | 06 | 1999 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $2,600 | $4,500 | Implemented |
DS0143 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $800 | $135 | Implemented |
DS0143 # 02 Y:1999 | 02 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,177 | $7,500 | Implemented |
DS0143 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,280 | $2,400 | Implemented |
DS0143 # 06 Y:1999 | 06 | 1999 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $16,043 | $640 | Implemented |
DS0143 # 07 Y:1999 | 07 | 1999 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $8,760 | $90 | Implemented |
TP0002 # 01 Y:1999 | 01 | 1999 | OPTIMIZE PLANT POWER FACTOR | $16,692 | $23,000 | Implemented |
TP0002 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,178 | $1,000 | Implemented |
TP0002 # 05 Y:1999 | 05 | 1999 | PAY UTILITY BILLS ON TIME | $1,514 | $0 | Implemented |
TP0002 # 07 Y:1999 | 07 | 1999 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $880 | $0 | Implemented |
TP0002 # 08 Y:1999 | 08 | 1999 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $342 | $0 | Implemented |
SD0220 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,040 | $5,528 | Implemented |
SD0220 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,440 | $500 | Implemented |
SD0220 # 04 Y:1999 | 04 | 1999 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $17,838 | $732 | Implemented |
SD0220 # 05 Y:1999 | 05 | 1999 | CONVERT TO AQUEOUS CLEANING | $7,548 | $0 | Implemented |
SD0220 # 06 Y:1999 | 06 | 1999 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $7,710 | $8,500 | Implemented |