Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
587
matching recommendationsSIC | 3443 | Fabricated Plate Work (boiler Shops) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0017 # 03 Y:1992 | 03 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,603 | $500 | Implemented |
IA0017 # 07 Y:1992 | 07 | 1992 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $6,834 | $22,000 | Implemented |
OK0381 # 01 Y:1992 | 01 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,587 | $150 | Implemented |
OK0381 # 02 Y:1992 | 02 | 1992 | INSULATE BARE EQUIPMENT | $374 | $1,389 | Implemented |
OK0381 # 03 Y:1992 | 03 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,360 | $1,185 | Implemented |
CO0246 # 01 Y:1992 | 01 | 1992 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,100 | $250 | Implemented |
CO0246 # 02 Y:1992 | 02 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $820 | $5 | Implemented |
CO0246 # 03 Y:1992 | 03 | 1992 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,120 | $1,300 | Implemented |
CO0246 # 04 Y:1992 | 04 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $190 | $10 | Implemented |
CO0246 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $28,500 | $29,730 | Implemented |
CO0246 # 06 Y:1992 | 06 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $190 | $10 | Implemented |
CO0246 # 07 Y:1992 | 07 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $360 | $310 | Implemented |
CO0246 # 09 Y:1992 | 09 | 1992 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $310 | $1,500 | Implemented |
AM0151 # 02 Y:1992 | 02 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,460 | $530 | Implemented |
AM0151 # 03 Y:1992 | 03 | 1992 | PAY UTILITY BILLS ON TIME | $920 | $0 | Implemented |
AM0151 # 04 Y:1992 | 04 | 1992 | INSTALL SET-BACK TIMERS | $730 | $300 | Implemented |
AM0151 # 05 Y:1992 | 05 | 1992 | INSTALL SET-BACK TIMERS | $460 | $0 | Implemented |
AM0151 # 06 Y:1992 | 06 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $460 | $0 | Implemented |
OK0332 # 01 Y:1990 | 01 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $1,937 | $900 | Implemented |
OK0332 # 03 Y:1990 | 03 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $98 | $102 | Implemented |
OK0332 # 04 Y:1990 | 04 | 1990 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,747 | $1,641 | Implemented |
OK0332 # 05 Y:1990 | 05 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,085 | $0 | Implemented |
OK0332 # 06 Y:1990 | 06 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,410 | $1,070 | Implemented |
MA0182 # 01 Y:1990 | 01 | 1990 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $5,921 | $116,600 | Implemented |
MA0182 # 02 Y:1990 | 02 | 1990 | INSTALL SET-BACK TIMERS | $368 | $440 | Implemented |