Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

587

matching recommendations
Reset
SIC 3443 Fabricated Plate Work (boiler Shops)
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0214 # 01 Y:1987 01 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $57 $43 Implemented
OK0214 # 02 Y:1987 02 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,929 $24,647 Implemented
OK0214 # 03 Y:1987 03 1987 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $638 $0 Implemented
OK0214 # 05 Y:1987 05 1987 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,319 $0 Implemented
OK0214 # 07 Y:1987 07 1987 INSTALL TIMERS AND/OR THERMOSTATS $1,059 $450 Implemented
UD0224 # 05 Y:1987 05 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,313 $2,500 Implemented
MA0061 # 01 Y:1986 01 1986 USE RADIANT HEATER FOR SPOT HEATING $721 $800 Implemented
MA0061 # 02 Y:1986 02 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,705 $300 Implemented
MA0061 # 03 Y:1986 03 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,390 $300 Implemented
MA0061 # 04 Y:1986 04 1986 INSTALL STORM WINDOWS AND DOORS $2,523 $6,945 Implemented
OK0187 # 01 Y:1986 01 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $116 $103 Implemented
OK0187 # 02 Y:1986 02 1986 INSTALL TIMERS AND/OR THERMOSTATS $277 $700 Implemented
OK0187 # 03 Y:1986 03 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $125 $40 Implemented
UD0182 # 01 Y:1985 01 1985 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $153,020 $24,416 Implemented
UD0182 # 02 Y:1985 02 1985 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,436 $0 Implemented
UD0182 # 03 Y:1985 03 1985 COVER OPEN TANKS $8,435 $1,100 Implemented
UD0182 # 06 Y:1985 06 1985 MINIMIZE WATER USAGE $38,577 $4,000 Implemented
UD0182 # 07 Y:1985 07 1985 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,516 $2,500 Implemented
UD0175 # 01 Y:1985 01 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $25,286 $48,000 Implemented
OK0179 # 02 Y:1985 02 1985 INSTALL TIMERS AND/OR THERMOSTATS $271 $600 Implemented
OK0179 # 03 Y:1985 03 1985 USE RADIANT HEATER FOR SPOT HEATING $12,890 $4,700 Implemented
OK0179 # 04 Y:1985 04 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $215 $248 Implemented
UD0172 # 01 Y:1985 01 1985 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $1,203 $150 Implemented
UD0172 # 02 Y:1985 02 1985 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,225 $50 Implemented
UD0172 # 03 Y:1985 03 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,195 $123 Implemented