Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,219
matching recommendationsSIC | 3443 | Fabricated Plate Work (boiler Shops) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0520 # 01 Y:2022 | 01 | 2022 | USE SYNTHETIC LUBRICANT | $540 | $0 | Not Implemented |
OK1062 # 02 Y:2022 | 02 | 2022 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,554 | $0 | Implemented |
OK1062 # 05 Y:2022 | 05 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,957 | $30,186 | Implemented |
OK1062 # 01 Y:2022 | 01 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,294 | $2,732 | Implemented |
OK1062 # 03 Y:2022 | 03 | 2022 | USE RADIANT HEATER FOR SPOT HEATING | $12,930 | $48,590 | Not Implemented |
OK1062 # 04 Y:2022 | 04 | 2022 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $101 | $580 | Implemented |
MZ0320 # 03 Y:2021 | 03 | 2021 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,470 | $9,762 | Not Implemented |
MZ0320 # 04 Y:2021 | 04 | 2021 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $12,708 | $15,605 | Implemented |
MZ0320 # 01 Y:2021 | 01 | 2021 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $10,092 | $12,000 | Not Implemented |
MZ0320 # 07 Y:2021 | 07 | 2021 | INSTALL OCCUPANCY SENSORS | $279 | $360 | Implemented |
MZ0320 # 06 Y:2021 | 06 | 2021 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $298 | $1,226 | Not Implemented |
MZ0320 # 05 Y:2021 | 05 | 2021 | INSULATE BARE EQUIPMENT | $375 | $389 | Not Implemented |
MZ0320 # 02 Y:2021 | 02 | 2021 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,821 | $240 | Implemented |
DL0197 # 04 Y:2021 | 04 | 2021 | INSTALL TIMERS AND/OR THERMOSTATS | $730 | $135 | Implemented |
DL0197 # 05 Y:2021 | 05 | 2021 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $2,034 | $1,300 | Implemented |
DL0197 # 01 Y:2021 | 01 | 2021 | USE OPTIMUM TEMPERATURE | $8,560 | $0 | Not Implemented |
DL0197 # 02 Y:2021 | 02 | 2021 | ADD AREA LIGHTING SWITCHES | $21,520 | $846 | Not Implemented |
DL0197 # 07 Y:2021 | 07 | 2021 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,810 | $1,098 | Not Implemented |
DL0197 # 08 Y:2021 | 08 | 2021 | REPLACE BOILER | $8,560 | $23,609 | Not Implemented |
DL0197 # 03 Y:2021 | 03 | 2021 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $9,710 | $0 | Implemented |
DL0197 # 09 Y:2021 | 09 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,313 | $39,529 | Implemented |
DL0197 # 06 Y:2021 | 06 | 2021 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $12,960 | $173,544 | Implemented |
DL0197 # 11 Y:2021 | 11 | 2021 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,320 | $14,125 | Not Implemented |
DL0197 # 10 Y:2021 | 10 | 2021 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $1,950 | $9,070 | Not Implemented |
MZ0316 # 07 Y:2021 | 07 | 2021 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $2,786 | $11,055 | Implemented |