Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,214
matching recommendationsSIC | 3443 | Fabricated Plate Work (boiler Shops) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0594 # 09 Y:2017 | 09 | 2017 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $261 | $200 | Not Implemented |
CO0732 # 01 Y:2016 | 01 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,620 | $12,560 | n/a |
CO0732 # 02 Y:2016 | 02 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,690 | $840 | n/a |
CO0732 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,070 | $46,190 | n/a |
CO0722 # 01 Y:2016 | 01 | 2016 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,390 | $0 | n/a |
CO0722 # 02 Y:2016 | 02 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $880 | $110 | n/a |
CO0722 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,500 | $21,280 | n/a |
CO0722 # 04 Y:2016 | 04 | 2016 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,910 | $560 | n/a |
CO0722 # 05 Y:2016 | 05 | 2016 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $4,830 | $6,980 | n/a |
CO0722 # 06 Y:2016 | 06 | 2016 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,180 | $0 | n/a |
CO0722 # 07 Y:2016 | 07 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $920 | $5,520 | n/a |
CO0722 # 08 Y:2016 | 08 | 2016 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,900 | $500 | n/a |
IA0552 # 01 Y:2016 | 01 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $64,982 | $104,231 | Implemented |
IA0552 # 02 Y:2016 | 02 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,488 | $35 | Not Implemented |
IA0552 # 03 Y:2016 | 03 | 2016 | INSTALL OCCUPANCY SENSORS | $4,046 | $2,600 | Implemented |
IA0552 # 04 Y:2016 | 04 | 2016 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,573 | $1 | Implemented |
IA0552 # 05 Y:2016 | 05 | 2016 | UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS | $2,612 | $280 | Not Implemented |
IA0552 # 06 Y:2016 | 06 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,216 | $390 | Implemented |
IA0552 # 07 Y:2016 | 07 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,487 | $35 | Not Implemented |
IA0552 # 08 Y:2016 | 08 | 2016 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $886 | $357 | Implemented |
AM0689 # 01 Y:2015 | 01 | 2015 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $10,100 | $5,270 | Implemented |
AM0689 # 02 Y:2015 | 02 | 2015 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $14,595 | $4,000 | Implemented |
AM0689 # 03 Y:2015 | 03 | 2015 | OPTIMIZE PLANT POWER FACTOR | $8,425 | $12,120 | Not Implemented |
AM0689 # 04 Y:2015 | 04 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,740 | $1,840 | Implemented |
AM0689 # 05 Y:2015 | 05 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,780 | $3,990 | Implemented |