Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
55
matching recommendationsSIC | 3444 | Sheet Metalwork |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0340 # 04 Y:1999 | 04 | 1999 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,051 | $0 | Implemented |
WI0340 # 03 Y:1999 | 03 | 1999 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $2,819 | $6,000 | Not Implemented |
WI0340 # 02 Y:1999 | 02 | 1999 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,971 | $0 | Not Implemented |
WI0319 # 06 Y:1998 | 06 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $214 | $0 | Implemented |
WI0319 # 05 Y:1998 | 05 | 1998 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,187 | $500 | Not Implemented |
WI0319 # 04 Y:1998 | 04 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,295 | $940 | Not Implemented |
WI0319 # 03 Y:1998 | 03 | 1998 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,599 | $18,400 | Not Implemented |
WI0319 # 02 Y:1998 | 02 | 1998 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $6,046 | $13,200 | Not Implemented |
WI0319 # 01 Y:1998 | 01 | 1998 | INSTALL SENSORS TO DETECT DEFECTS | $69,212 | $63,760 | Not Implemented |
WI0291 # 01 Y:1997 | 01 | 1997 | ELIMINATE SHIFT | $23,000 | $5,000 | Not Implemented |
WI0291 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,229 | $20,892 | Implemented |
WI0291 # 03 Y:1997 | 03 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,099 | $360 | Implemented |
WI0291 # 04 Y:1997 | 04 | 1997 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,451 | $10,000 | Not Implemented |
WI0291 # 06 Y:1997 | 06 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,693 | $0 | Implemented |
WI0291 # 07 Y:1997 | 07 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $15,852 | $0 | Not Implemented |
WI0291 # 05 Y:1997 | 05 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,429 | $740 | Not Implemented |
WI0269 # 02 Y:1996 | 02 | 1996 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $22,707 | $0 | Not Implemented |
WI0269 # 03 Y:1996 | 03 | 1996 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $16,770 | $25,000 | Not Implemented |
WI0269 # 04 Y:1996 | 04 | 1996 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $14,920 | $22,000 | Implemented |
WI0269 # 05 Y:1996 | 05 | 1996 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $5,044 | $17,980 | Implemented |
WI0269 # 06 Y:1996 | 06 | 1996 | SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS | $4,367 | $0 | Not Implemented |
WI0269 # 07 Y:1996 | 07 | 1996 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $3,269 | $0 | Implemented |
WI0269 # 08 Y:1996 | 08 | 1996 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,458 | $7,500 | Not Implemented |
WI0269 # 09 Y:1996 | 09 | 1996 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $1,973 | $6,000 | Not Implemented |
WI0269 # 10 Y:1996 | 10 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,653 | $180 | Implemented |