Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
437
matching recommendationsSIC | 345 | Screw Machine Products, Bolts, Etc. |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0139 # 10 Y:1999 | 10 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $3,154 | $9,500 | Implemented |
AM0353 # 03 Y:1999 | 03 | 1999 | REDUCE SCRAP PRODUCTION | $30,900 | $0 | Implemented |
AM0353 # 04 Y:1999 | 04 | 1999 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $8,100 | $8,500 | Implemented |
AM0353 # 05 Y:1999 | 05 | 1999 | MAINTAIN MACHINES TO REDUCE LEAKS | $2,700 | $500 | Implemented |
AM0353 # 06 Y:1999 | 06 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,360 | $0 | Implemented |
AM0353 # 07 Y:1999 | 07 | 1999 | PAY BILLS ON TIME TO AVOID LATE FEES | $1,649 | $0 | Implemented |
AM0353 # 09 Y:1999 | 09 | 1999 | INSULATE BARE EQUIPMENT | $1,030 | $81 | Implemented |
AM0353 # 10 Y:1999 | 10 | 1999 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $920 | $0 | Implemented |
AM0353 # 11 Y:1999 | 11 | 1999 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $600 | $0 | Implemented |
AM0353 # 12 Y:1999 | 12 | 1999 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $557 | $0 | Implemented |
AM0353 # 13 Y:1999 | 13 | 1999 | INSTALL SKYLIGHTS | $300 | $1,400 | Implemented |
AM0353 # 14 Y:1999 | 14 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $240 | $250 | Implemented |
ND0321 # 01 Y:1999 | 01 | 1999 | PURCHASE RE-CONDITIONED MATERIAL INSTEAD OF NEW | $103,932 | $0 | Implemented |
ND0321 # 04 Y:1999 | 04 | 1999 | UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID | $1,555 | $7,050 | Implemented |
ND0321 # 05 Y:1999 | 05 | 1999 | OPTIMIZE PLANT POWER FACTOR | $2,989 | $12,575 | Implemented |
ND0321 # 08 Y:1999 | 08 | 1999 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $730 | $125 | Implemented |
ND0321 # 10 Y:1999 | 10 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $158 | $130 | Implemented |
MA0439 # 02 Y:1999 | 02 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $8,636 | $1,360 | Implemented |
MA0439 # 03 Y:1999 | 03 | 1999 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,629 | $500 | Implemented |
MA0439 # 05 Y:1999 | 05 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,038 | $1,295 | Implemented |
AS0247 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $498 | $20 | Implemented |
AS0247 # 03 Y:1999 | 03 | 1999 | INSTALL OCCUPANCY SENSORS | $587 | $1,275 | Implemented |
AS0247 # 04 Y:1999 | 04 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $226 | $253 | Implemented |
AS0247 # 07 Y:1999 | 07 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $19,300 | $120 | Implemented |
AS0247 # 08 Y:1999 | 08 | 1999 | ADD ADDITIONAL PRODUCTION SHIFT | $25,200 | $24,000 | Implemented |