matching recommendationsSIC | 345 | Screw Machine Products, Bolts, Etc. |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0508 # 05 Y:2002 | 05 | 2002 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $115,000 | $100,000 | Not Implemented |
CO0508 # 04 Y:2002 | 04 | 2002 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $31,960 | $1,620 | Implemented |
CO0508 # 03 Y:2002 | 03 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,570 | $23,500 | Not Implemented |
CO0508 # 02 Y:2002 | 02 | 2002 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $4,230 | $7,000 | Implemented |
CO0508 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,450 | $90 | Implemented |
IC0035 # 12 Y:2002 | 12 | 2002 | AUTOMATE PAYROLL SYSTEM | $19,800 | $8,785 | Not Implemented |
IC0035 # 02 Y:2002 | 02 | 2002 | INSULATE BARE EQUIPMENT | $12,947 | $2,657 | Implemented |
IC0035 # 01 Y:2002 | 01 | 2002 | ADJUST BURNERS FOR EFFICIENT OPERATION | $3,252 | $1,500 | Not Implemented |
IC0035 # 03 Y:2002 | 03 | 2002 | INSULATE BARE EQUIPMENT | $11,300 | $7,092 | Not Implemented |
IC0035 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,174 | $1,400 | Not Implemented |
IC0035 # 05 Y:2002 | 05 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,103 | $83,780 | Implemented |
IC0035 # 08 Y:2002 | 08 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,977 | $4,813 | Implemented |
IC0035 # 09 Y:2002 | 09 | 2002 | RECOVER AND REUSE WASTE MATERIAL | $97 | $120 | Implemented |
OR0409 # 01 Y:2002 | 01 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,115 | $33,646 | Not Implemented |
IC0035 # 06 Y:2002 | 06 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,785 | $2,130 | Not Implemented |
IC0035 # 10 Y:2002 | 10 | 2002 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $4,000 | $3,500 | Implemented |
IC0035 # 11 Y:2002 | 11 | 2002 | INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE | $4,885 | $3,000 | Not Implemented |
IC0035 # 07 Y:2002 | 07 | 2002 | INSTALL OCCUPANCY SENSORS | $9,366 | $6,890 | Not Implemented |
OR0409 # 05 Y:2002 | 05 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,749 | $0 | Implemented |
OR0409 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,472 | $3,500 | Implemented |
OR0409 # 03 Y:2002 | 03 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,676 | $560 | Implemented |
OR0409 # 02 Y:2002 | 02 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,918 | $3,031 | Not Implemented |
WI0414 # 03 Y:2002 | 03 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,225 | $0 | Implemented |
WI0414 # 08 Y:2002 | 08 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $754 | $350 | Implemented |
WI0414 # 01 Y:2002 | 01 | 2002 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $13,469 | $1,800 | Not Implemented |