Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
54
matching recommendationsSIC | 3452 | Bolts, Nuts, Rivets, And Washers |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0342 # 06 Y:2004 | 06 | 2004 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $6,459 | $7,965 | Not Implemented |
SD0342 # 05 Y:2004 | 05 | 2004 | INSULATE BARE EQUIPMENT | $7,120 | $470 | Not Implemented |
SD0342 # 03 Y:2004 | 03 | 2004 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $26,802 | $24,875 | Not Implemented |
SD0342 # 01 Y:2004 | 01 | 2004 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $132,869 | $208,000 | Not Implemented |
SD0342 # 04 Y:2004 | 04 | 2004 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $8,450 | $18,000 | Not Implemented |
SD0330 # 06 Y:2003 | 06 | 2003 | AUTOMATE FINISHING PROCESS | $96,800 | $200,000 | Not Implemented |
SD0330 # 05 Y:2003 | 05 | 2003 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,500 | $10,000 | Not Implemented |
SD0330 # 04 Y:2003 | 04 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $887 | $80 | Implemented |
SD0330 # 03 Y:2003 | 03 | 2003 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,836 | $4,000 | Not Implemented |
SD0330 # 02 Y:2003 | 02 | 2003 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,189 | $6,000 | Not Implemented |
SD0330 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $20,782 | $1,425 | Not Implemented |
SD0141 # 01 Y:1996 | 01 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $5,869 | $13,500 | Not Implemented |
SD0141 # 02 Y:1996 | 02 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,412 | $1,200 | Not Implemented |
SD0141 # 03 Y:1996 | 03 | 1996 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $1,057 | $2,600 | Not Implemented |
SD0141 # 04 Y:1996 | 04 | 1996 | SEPARATE TREATMENTS FOR EACH TYPE OF SOLUTION AND RECYCLE | $7,840 | $6,000 | Not Implemented |
SD0041 # 08 Y:1993 | 08 | 1993 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,037 | $0 | Not Implemented |
SD0041 # 07 Y:1993 | 07 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $22,031 | $300 | Not Implemented |
SD0041 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $735 | $1,980 | Implemented |
SD0041 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,135 | $700 | Implemented |
SD0041 # 04 Y:1993 | 04 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $17,058 | $5,430 | Implemented |
SD0041 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,909 | $0 | Implemented |
SD0041 # 02 Y:1993 | 02 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,042 | $20 | Implemented |
SD0041 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $960 | $1,377 | Implemented |
SD0038 # 05 Y:1992 | 05 | 1992 | INSTALL SET-BACK TIMERS | $750 | $909 | Not Implemented |
SD0038 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,307 | $950 | Not Implemented |