Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,616
matching recommendationsSIC | 346 | Metal Forgings And Stampings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0858 # 03 Y:2012 | 03 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,006 | $500 | Implemented |
UD0858 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,010 | $1,000 | Implemented |
UD0858 # 05 Y:2012 | 05 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $399 | $300 | Not Implemented |
UD0858 # 06 Y:2012 | 06 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $409 | $360 | Not Implemented |
UM0406 # 01 Y:2012 | 01 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $48,738 | $10,000 | Not Implemented |
UM0406 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,375 | $7,720 | Implemented |
UM0406 # 03 Y:2012 | 03 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $12,063 | $3,600 | Implemented |
UM0406 # 04 Y:2012 | 04 | 2012 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $37,146 | $1,000 | Not Implemented |
UM0406 # 05 Y:2012 | 05 | 2012 | IMPROVE COMBUSTION CONTROL CAPABILITY | $16,585 | $25,000 | Not Implemented |
UM0406 # 06 Y:2012 | 06 | 2012 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $15,780 | $10,000 | Not Implemented |
TT0091 # 01 Y:2012 | 01 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,974 | $3,000 | Implemented |
TT0091 # 02 Y:2012 | 02 | 2012 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $170 | $20 | Not Implemented |
TT0091 # 03 Y:2012 | 03 | 2012 | INSTALL OCCUPANCY SENSORS | $688 | $350 | Implemented |
TT0091 # 04 Y:2012 | 04 | 2012 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $3,203 | $0 | Implemented |
WM0001 # 01 Y:2012 | 01 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $435 | $200 | Implemented |
WM0001 # 02 Y:2012 | 02 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $362 | $30 | Implemented |
WM0001 # 03 Y:2012 | 03 | 2012 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $488 | $0 | Not Implemented |
WM0001 # 04 Y:2012 | 04 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,696 | $0 | Not Implemented |
WM0001 # 05 Y:2012 | 05 | 2012 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $27,100 | $78,000 | Not Implemented |
WM0001 # 06 Y:2012 | 06 | 2012 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $236 | $79 | Not Implemented |
WM0001 # 07 Y:2012 | 07 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $141 | $1,000 | Implemented |
WM0001 # 08 Y:2012 | 08 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,227 | $1,535 | Implemented |
UA0082 # 01 Y:2012 | 01 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $89,005 | $0 | Not Implemented |
UA0082 # 02 Y:2012 | 02 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $25,747 | $24,000 | Not Implemented |
UA0082 # 03 Y:2012 | 03 | 2012 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $21,616 | $1,199 | Not Implemented |