matching recommendationsSIC | 346 | Metal Forgings And Stampings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0016 # 01 Y:2012 | 01 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,622 | $488 | Not Implemented |
WM0016 # 07 Y:2012 | 07 | 2012 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $962 | $5,000 | Not Implemented |
WM0016 # 06 Y:2012 | 06 | 2012 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $2,004 | $0 | Implemented |
WM0016 # 04 Y:2012 | 04 | 2012 | INSTALL OCCUPANCY SENSORS | $957 | $270 | Not Implemented |
WM0016 # 02 Y:2012 | 02 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $652 | $850 | Not Implemented |
WM0016 # 05 Y:2012 | 05 | 2012 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,769 | $13,000 | Not Implemented |
WM0016 # 03 Y:2012 | 03 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,517 | $0 | Implemented |
UM0415 # 04 Y:2012 | 04 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,832 | $10,965 | Not Implemented |
UM0415 # 05 Y:2012 | 05 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $23,600 | $1,000 | Implemented |
UM0415 # 03 Y:2012 | 03 | 2012 | OPTIMIZE PLANT POWER FACTOR | $12,081 | $20,000 | Not Implemented |
UM0415 # 02 Y:2012 | 02 | 2012 | INSTALL OCCUPANCY SENSORS | $822 | $875 | Implemented |
UM0415 # 01 Y:2012 | 01 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $8,072 | $4,000 | Not Implemented |
UM0415 # 06 Y:2012 | 06 | 2012 | INSULATE BARE EQUIPMENT | $1,697 | $1,500 | Not Implemented |
UA3023 # 08 Y:2012 | 08 | 2012 | DISCONNECT BALLASTS | $4,820 | $810 | Implemented |
UA3023 # 09 Y:2012 | 09 | 2012 | DISCONNECT BALLASTS | $3,927 | $810 | Implemented |
UA3023 # 10 Y:2012 | 10 | 2012 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,216 | $430 | Not Implemented |
UA3023 # 04 Y:2012 | 04 | 2012 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,914 | $180 | Implemented |
UA3023 # 03 Y:2012 | 03 | 2012 | INSTALL TIMERS AND/OR THERMOSTATS | $9,242 | $680 | Not Implemented |
UA3023 # 01 Y:2012 | 01 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $90,505 | $55,107 | Not Implemented |
UA3023 # 02 Y:2012 | 02 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $27,110 | $2,162 | Not Implemented |
UA3023 # 05 Y:2012 | 05 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $28,652 | $2,400 | Not Implemented |
UA3023 # 06 Y:2012 | 06 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $26,924 | $9,695 | Not Implemented |
UA3023 # 07 Y:2012 | 07 | 2012 | DISCONNECT BALLASTS | $6,783 | $1,013 | Implemented |
UK1212 # 07 Y:2012 | 07 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,205 | $4,270 | Not Implemented |
UK1212 # 02 Y:2012 | 02 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $14,492 | $15,000 | Not Implemented |