IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

34

matching recommendations
Reset
SIC 3462 Iron And Steel Forgings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0295 # 10 Y:2006 10 2006 USE PHOTOCELL CONTROLS $878 $736 Not Implemented
UM0295 # 01 Y:2006 01 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $80,138 $170,000 Implemented
UM0295 # 02 Y:2006 02 2006 OPTIMIZE PLANT POWER FACTOR $71,400 $75,000 Not Implemented
UM0295 # 03 Y:2006 03 2006 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE $15,365 $1,130 Not Implemented
UM0295 # 04 Y:2006 04 2006 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $10,656 $5,250 Not Implemented
UM0295 # 05 Y:2006 05 2006 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $8,859 $2,400 Not Implemented
UM0295 # 06 Y:2006 06 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $7,040 $1,200 Implemented
UM0295 # 07 Y:2006 07 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,767 $13,877 Not Implemented
UM0295 # 08 Y:2006 08 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,259 $3,080 Not Implemented
UM0295 # 09 Y:2006 09 2006 INSULATE BARE EQUIPMENT $1,316 $1,860 Not Implemented
UM0170 # 05 Y:2000 05 2000 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $11,573 $8,200 Not Implemented
UM0170 # 04 Y:2000 04 2000 RECOVER WASTE HEAT FROM EQUIPMENT $64,245 $22,000 Not Implemented
UM0170 # 03 Y:2000 03 2000 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $185,532 $310,000 Not Implemented
UM0170 # 02 Y:2000 02 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,147 $500 Implemented
UM0170 # 01 Y:2000 01 2000 INSTALL OCCUPANCY SENSORS $709 $1,660 Implemented
UM0042 # 05 Y:1995 05 1995 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $8,994 $2,960 n/a
UM0042 # 06 Y:1995 06 1995 INSULATE BARE EQUIPMENT $7,633 $2,650 n/a
UM0042 # 04 Y:1995 04 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,959 $350 n/a
UM0042 # 03 Y:1995 03 1995 OPTIMIZE PLANT POWER FACTOR $27,333 $85,000 n/a
UM0042 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,676 $21,703 n/a
UM0042 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,315 $12,150 n/a
ND0171 # 02 Y:1993 02 1993 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $17,072 $60,040 Not Implemented
ND0171 # 01 Y:1993 01 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,964 $4,533 Not Implemented
ND0171 # 03 Y:1993 03 1993 OPTIMIZE PLANT POWER FACTOR $12,500 $22,673 Not Implemented
ND0171 # 04 Y:1993 04 1993 HEAT TREAT PARTS ONLY TO REQUIRED SPECIFICATIONS OR STANDARDS $7,558 $8,500 Not Implemented