Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

61

matching recommendations
Reset
SIC 3463 Nonferrous Forgings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0272 # 05 Y:2001 05 2001 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $5,172 $7,600 Implemented
SD0272 # 01 Y:2001 01 2001 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $22,159 $5,200 Implemented
SD0272 # 03 Y:2001 03 2001 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $54,857 $120,000 Implemented
SD0272 # 04 Y:2001 04 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,213 $400 Implemented
SD0190 # 06 Y:1998 06 1998 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,072 $0 Implemented
SD0190 # 01 Y:1998 01 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $7,869 $11,580 Implemented
SD0190 # 05 Y:1998 05 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,620 $1,350 Implemented
SD0190 # 11 Y:1998 11 1998 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $9,500 $9,000 Implemented
SD0190 # 10 Y:1998 10 1998 INSTALL SPECTRAL REFLECTORS / DELAMP $2,302 $2,150 Implemented
SD0190 # 09 Y:1998 09 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,443 $6,942 Implemented
ND0278 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $209 $754 Implemented
ND0278 # 02 Y:1997 02 1997 ADD AREA LIGHTING SWITCHES $327 $200 Implemented
ND0278 # 04 Y:1997 04 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $196 $450 Implemented
ND0278 # 08 Y:1997 08 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,578 $2,925 Implemented
ND0278 # 11 Y:1997 11 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $242 $200 Implemented
ND0278 # 15 Y:1997 15 1997 SELL COMBUSTIBLE WASTE $4,950 $1,000 Implemented
ND0278 # 20 Y:1997 20 1997 IMPLEMENT A MACHINE AND COOLANT SUMP CLEANING PROGRAM TO MINIMIZE COOLANT CONTAMINATION $852 $3,000 Implemented
SD0155 # 07 Y:1996 07 1996 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $4,318 $1,100 Implemented
SD0155 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $27,898 $58,420 Implemented
SD0155 # 02 Y:1996 02 1996 COVER OPEN TANKS $254 $364 Implemented
SD0155 # 08 Y:1996 08 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,662 $500 Implemented
SD0155 # 09 Y:1996 09 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,351 $2,902 Implemented
SD0155 # 11 Y:1996 11 1996 INSTALL OCCUPANCY SENSORS $1,816 $779 Implemented
SD0155 # 12 Y:1996 12 1996 REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS $1,281 $0 Implemented
SD0155 # 05 Y:1996 05 1996 INSULATE BARE EQUIPMENT $1,165 $158 Implemented