IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

619

matching recommendations
Reset
SIC 3465 Automotive Stampings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TT0200 # 07 Y:2017 07 2017 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,772 $1,000 Implemented
UD0976 # 01 Y:2017 01 2017 OPTIMIZE PLANT POWER FACTOR $2,704 $1,000 Not Implemented
UD0976 # 02 Y:2017 02 2017 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $11,604 $10,000 Not Implemented
UD0976 # 03 Y:2017 03 2017 REDUCE VENTILATION AIR $2,584 $3,000 Not Implemented
UD0976 # 04 Y:2017 04 2017 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $471 $0 Not Implemented
UD0976 # 05 Y:2017 05 2017 UPGRADE CONTROLS ON COMPRESSORS $8,352 $21,000 Not Implemented
UD0976 # 06 Y:2017 06 2017 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,239 $30 Not Implemented
UD0976 # 07 Y:2017 07 2017 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,559 $2,000 Not Implemented
UD0976 # 08 Y:2017 08 2017 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $10,903 $1,500 Not Implemented
UD0976 # 09 Y:2017 09 2017 INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS $3,345 $10,950 Not Implemented
UD0976 # 10 Y:2017 10 2017 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,649 $0 Not Implemented
UD0976 # 11 Y:2017 11 2017 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,012 $0 Not Implemented
UD0976 # 12 Y:2017 12 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,115 $31,736 Not Implemented
UD0976 # 13 Y:2017 13 2017 INSTALL OCCUPANCY SENSORS $992 $1,230 Not Implemented
UD0976 # 14 Y:2017 14 2017 ADD AREA LIGHTING SWITCHES $671 $180 Not Implemented
UD0976 # 15 Y:2017 15 2017 INSULATE BARE EQUIPMENT $102 $420 Not Implemented
TR0003 # 01 Y:2017 01 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $41,044 $64,592 Implemented
TR0003 # 02 Y:2017 02 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $32,843 $2,000 Implemented
TR0003 # 03 Y:2017 03 2017 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,334 $14,764 Not Implemented
TR0003 # 04 Y:2017 04 2017 APPLY FOR INVESTMENT INCENTIVES $74,012 $15,000 Implemented
TR0003 # 05 Y:2017 05 2017 MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT $24,242 $38,964 Implemented
TR0003 # 06 Y:2017 06 2017 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $14,265 $449 Not Implemented
TR0003 # 07 Y:2017 07 2017 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $10,954 $10,000 Implemented
UA0173 # 01 Y:2017 01 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $62,936 $136,836 Not Implemented
UA0173 # 02 Y:2017 02 2017 USE PHOTOCELL CONTROLS $5,531 $2,748 Implemented