Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,577
matching recommendationsSIC | 347 | Metal Services, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0436 # 04 Y:2013 | 04 | 2013 | INSTALL OCCUPANCY SENSORS | $864 | $2,751 | Not Implemented |
SF0436 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,275 | $12,405 | Not Implemented |
SF0436 # 06 Y:2013 | 06 | 2013 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $608 | $2,400 | Not Implemented |
UD0876 # 09 Y:2013 | 09 | 2013 | REDUCE WATER USE WITH COUNTER CURRENT RINSING | $1,245 | $1,000 | Not Implemented |
UD0876 # 10 Y:2013 | 10 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $706 | $1,000 | Implemented |
UD0876 # 11 Y:2013 | 11 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $489 | $50 | Not Implemented |
UD0876 # 12 Y:2013 | 12 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $10,039 | $15,000 | Implemented |
UD0876 # 13 Y:2013 | 13 | 2013 | AIR CONDITION ONLY SPACE NECESSARY | $1,344 | $0 | Implemented |
UD0876 # 01 Y:2013 | 01 | 2013 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $25,570 | $0 | Implemented |
UD0876 # 02 Y:2013 | 02 | 2013 | OPTIMIZE PLANT POWER FACTOR | $3,308 | $12,000 | Not Implemented |
UD0876 # 03 Y:2013 | 03 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,184 | $0 | Implemented |
UD0876 # 04 Y:2013 | 04 | 2013 | BASE UTILITY CHARGES ON USAGE RATHER THAN AREA OCCUPIED | $1,416 | $1,400 | Implemented |
UD0876 # 05 Y:2013 | 05 | 2013 | INSTALL OCCUPANCY SENSORS | $5,943 | $6,500 | Implemented |
UD0876 # 06 Y:2013 | 06 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,557 | $0 | Implemented |
UD0876 # 07 Y:2013 | 07 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $630 | $0 | Implemented |
UD0876 # 08 Y:2013 | 08 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,009 | $14,325 | Not Implemented |
WM0021 # 01 Y:2013 | 01 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $483 | $184 | Not Implemented |
WM0021 # 02 Y:2013 | 02 | 2013 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $456 | $0 | Not Implemented |
WM0021 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $263 | $225 | Not Implemented |
WM0021 # 04 Y:2013 | 04 | 2013 | REDUCE DELIVERY SCHEDULES | $732 | $0 | Not Implemented |
WM0021 # 05 Y:2013 | 05 | 2013 | INSULATE BARE EQUIPMENT | $234 | $47 | Not Implemented |
WM0021 # 06 Y:2013 | 06 | 2013 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $992 | $1,544 | Not Implemented |
WM0021 # 07 Y:2013 | 07 | 2013 | USE OPTIMUM THICKNESS INSULATION | $118 | $325 | Not Implemented |
WM0021 # 08 Y:2013 | 08 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $170 | $32 | Not Implemented |
WM0021 # 09 Y:2013 | 09 | 2013 | INSTALL STORM WINDOWS AND DOORS | $57 | $16 | Not Implemented |