Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
191
matching recommendationsSIC | 347 | Metal Services, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0376 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,368 | $36,732 | Implemented |
UM0366 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $139 | $1,000 | Not Implemented |
UM0366 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,000 | $14,000 | n/a |
UM0366 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $200 | $200 | n/a |
UM0366 # 05 Y:2010 | 05 | 2010 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $85 | $31 | Implemented |
UM0366 # 04 Y:2010 | 04 | 2010 | INSULATE BARE EQUIPMENT | $2,117 | $596 | Implemented |
UM0358 # 07 Y:2009 | 07 | 2009 | INSULATE BARE EQUIPMENT | $5,125 | $11,770 | Implemented |
UM0358 # 06 Y:2009 | 06 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $44,552 | $36,000 | Implemented |
UM0358 # 05 Y:2009 | 05 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $69 | $62 | Implemented |
UM0358 # 04 Y:2009 | 04 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,766 | $1,200 | Not Implemented |
UM0358 # 03 Y:2009 | 03 | 2009 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $4,994 | $10,960 | Not Implemented |
UM0358 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,988 | $23,603 | Implemented |
UM0358 # 01 Y:2009 | 01 | 2009 | ISOLATE HOT OR COLD EQUIPMENT | $21,998 | $720 | Implemented |
UM0333 # 05 Y:2007 | 05 | 2007 | REDESIGN PROCESS | $2,329 | $3,480 | Not Implemented |
UM0333 # 01 Y:2007 | 01 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $19,901 | $2,000 | Implemented |
UM0333 # 02 Y:2007 | 02 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,803 | $50,000 | Not Implemented |
UM0333 # 03 Y:2007 | 03 | 2007 | REDUCE VENTILATION AIR | $8,623 | $100 | Implemented |
UM0333 # 06 Y:2007 | 06 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,506 | $1,060 | Not Implemented |
UM0333 # 07 Y:2007 | 07 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,455 | $100 | Implemented |
UM0333 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,589 | $3,480 | Implemented |
UM0300 # 01 Y:2006 | 01 | 2006 | INSULATE BARE EQUIPMENT | $15,780 | $14,167 | Implemented |
UM0300 # 02 Y:2006 | 02 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,203 | $2,500 | Implemented |
UM0300 # 03 Y:2006 | 03 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,520 | $515 | Implemented |
UM0300 # 04 Y:2006 | 04 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,993 | $500 | Implemented |
UM0300 # 07 Y:2006 | 07 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $537 | $1,000 | Implemented |