Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
154
matching recommendationsSIC | 347 | Metal Services, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
HO0212 # 06 Y:1999 | 06 | 1999 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,548 | $2,882 | Implemented |
HO0212 # 07 Y:1999 | 07 | 1999 | CHANGE OPERATING CONDITIONS | $8,954 | $20,000 | Not Implemented |
HO0212 # 08 Y:1999 | 08 | 1999 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $11,437 | $2,882 | Implemented |
HO0212 # 09 Y:1999 | 09 | 1999 | MOVE PRODUCT USING MECHANICAL MEANS | $4,590 | $12,000 | Not Implemented |
HO0212 # 10 Y:1999 | 10 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $6,379 | $500 | Implemented |
HO0200 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,818 | $7,776 | Implemented |
HO0200 # 02 Y:1999 | 02 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,223 | $3,065 | Implemented |
HO0200 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $944 | $1,500 | Not Implemented |
HO0200 # 04 Y:1999 | 04 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $451 | $100 | Not Implemented |
HO0200 # 05 Y:1999 | 05 | 1999 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $7,395 | $4,800 | Implemented |
HO0200 # 06 Y:1999 | 06 | 1999 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $14,628 | $8,000 | Not Implemented |
HO0200 # 07 Y:1999 | 07 | 1999 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $25,402 | $22,000 | Not Implemented |
HO0200 # 08 Y:1999 | 08 | 1999 | INSTALL AUTOMATIC PACKING EQUIPMENT | $10,000 | $35,000 | Not Implemented |
MA0340 # 01 Y:1995 | 01 | 1995 | USE POWER DURING OFF-PEAK PERIODS | $4,800 | $0 | Implemented |
MA0340 # 02 Y:1995 | 02 | 1995 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,349 | $200 | Implemented |
MA0340 # 03 Y:1995 | 03 | 1995 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,634 | $5,995 | Not Implemented |
MA0340 # 04 Y:1995 | 04 | 1995 | PAY UTILITY BILLS ON TIME | $1,820 | $0 | Implemented |
MA0340 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,369 | $2,464 | Implemented |
MA0340 # 06 Y:1995 | 06 | 1995 | REDUCE VENTILATION AIR | $1,190 | $3,320 | Implemented |
MA0340 # 07 Y:1995 | 07 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $753 | $0 | Implemented |
MA0340 # 08 Y:1995 | 08 | 1995 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $612 | $330 | Implemented |
MA0340 # 09 Y:1995 | 09 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $558 | $127 | Not Implemented |
MA0340 # 10 Y:1995 | 10 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $356 | $570 | Implemented |
MA0339 # 01 Y:1995 | 01 | 1995 | BURN A LESS EXPENSIVE GRADE OF FUEL | $4,128 | $1,860 | Implemented |
MA0339 # 02 Y:1995 | 02 | 1995 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $1,027 | $3,770 | Implemented |