Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,577

matching recommendations
Reset
SIC 347 Metal Services, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
HO0200 # 07 Y:1999 07 1999 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $25,402 $22,000 Not Implemented
HO0200 # 08 Y:1999 08 1999 INSTALL AUTOMATIC PACKING EQUIPMENT $10,000 $35,000 Not Implemented
OD0131 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $416 $900 Not Implemented
OD0131 # 02 Y:1999 02 1999 INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS $4,051 $3,290 Not Implemented
OD0131 # 03 Y:1999 03 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,972 $800 Not Implemented
OD0131 # 04 Y:1999 04 1999 TURN OFF EQUIPMENT WHEN NOT IN USE $2,202 $0 Not Implemented
UM0133 # 01 Y:1999 01 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,000 $2,000 Implemented
UM0133 # 02 Y:1999 02 1999 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $35,000 $43,000 Implemented
UM0133 # 03 Y:1999 03 1999 MINIMIZE WATER USAGE $35,600 $5,500 Implemented
UM0133 # 04 Y:1999 04 1999 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $21,232 $14,700 Implemented
UM0133 # 05 Y:1999 05 1999 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $259,748 $13,300 Implemented
UM0133 # 06 Y:1999 06 1999 USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL $307,747 $800,000 n/a
UM0133 # 07 Y:1999 07 1999 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $25,360 $15,700 Not Implemented
DS0126 # 01 Y:1999 01 1999 CONTRACT A WOOD PALLET RECYCLING COMPANY $1,040 $160 Not Implemented
DS0126 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,141 $20 Implemented
DS0126 # 03 Y:1999 03 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $434 $750 Implemented
DS0126 # 04 Y:1999 04 1999 BURN A LESS EXPENSIVE GRADE OF FUEL $27,478 $91,571 Implemented
DS0126 # 05 Y:1999 05 1999 RECOVER WASTE HEAT FROM EQUIPMENT $3,077 $6,500 Not Implemented
DS0126 # 06 Y:1999 06 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $34,638 $78,656 Implemented
DS0126 # 07 Y:1999 07 1999 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE $7,897 $1,350 Not Implemented
DS0126 # 08 Y:1999 08 1999 IMPROVE SPACE COMFORT CONDITIONING $22,680 $270 Implemented
CO0429 # 01 Y:1998 01 1998 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $840 $1,000 Implemented
CO0429 # 02 Y:1998 02 1998 CLOSELY MONITOR CHEMICAL ADDITIONS TO INCREASE BATH LIFE $4,860 $0 Implemented
CO0429 # 03 Y:1998 03 1998 ALLOW DRAINAGE BEFORE WITHDRAWING OBJECT $2,930 $800 Not Implemented
CO0429 # 04 Y:1998 04 1998 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $6,000 $10,160 Implemented