Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
67
matching recommendationsSIC | 347 | Metal Services, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0215 # 08 Y:1997 | 08 | 1997 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $192 | $15 | Not Implemented |
AS0215 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,408 | $2,681 | Implemented |
AS0215 # 02 Y:1997 | 02 | 1997 | INSTALL OCCUPANCY SENSORS | $185 | $450 | Implemented |
AS0215 # 06 Y:1997 | 06 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $534 | $30 | Implemented |
AS0215 # 04 Y:1997 | 04 | 1997 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,409 | $1,500 | Not Implemented |
AS0215 # 03 Y:1997 | 03 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $371 | $315 | Not Implemented |
AS0215 # 05 Y:1997 | 05 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $564 | $480 | Implemented |
AS0215 # 09 Y:1997 | 09 | 1997 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $16,847 | $43,100 | Not Implemented |
AS0215 # 07 Y:1997 | 07 | 1997 | IMPROVE HANDLING PRACTICES | $370 | $0 | Implemented |
MA0400 # 01 Y:1997 | 01 | 1997 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $347,702 | $505,000 | Not Implemented |
MA0400 # 05 Y:1997 | 05 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $388 | $0 | Implemented |
MA0400 # 02 Y:1997 | 02 | 1997 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $17,497 | $92,676 | Not Implemented |
MA0400 # 03 Y:1997 | 03 | 1997 | COVER OPEN TANKS | $15,677 | $6,578 | Implemented |
MA0400 # 04 Y:1997 | 04 | 1997 | INSULATE BARE EQUIPMENT | $605 | $970 | Not Implemented |
AS0206 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,393 | $2,503 | Not Implemented |
AS0206 # 08 Y:1997 | 08 | 1997 | DEMOLISH OLD BUILDING TO REDUCE TAX AND INSURANCE BILLS | $12,000 | $100 | Not Implemented |
AS0206 # 02 Y:1997 | 02 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,330 | $220 | Implemented |
AS0206 # 01 Y:1997 | 01 | 1997 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $10,800 | $7,000 | Not Implemented |
AS0205 # 11 Y:1997 | 11 | 1997 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $2,076 | $30 | Implemented |
AS0205 # 09 Y:1997 | 09 | 1997 | TREAT AND REUSE RINSE WATERS | $4,004 | $950 | Not Implemented |
AS0205 # 08 Y:1997 | 08 | 1997 | INSTALL OCCUPANCY SENSORS | $1,348 | $1,425 | Not Implemented |
AS0205 # 06 Y:1997 | 06 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $714 | $40 | Implemented |
AS0205 # 05 Y:1997 | 05 | 1997 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $8,943 | $7,500 | Not Implemented |
AS0205 # 03 Y:1997 | 03 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $815 | $70 | Implemented |
AS0205 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,290 | $7,006 | Not Implemented |