Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
138
matching recommendationsSIC | 3471 | Plating And Polishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0436 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,275 | $12,405 | Not Implemented |
SF0436 # 06 Y:2013 | 06 | 2013 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $608 | $2,400 | Not Implemented |
LM0123 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,533 | $33,000 | Not Implemented |
LM0123 # 02 Y:2007 | 02 | 2007 | COVER OPEN TANKS | $7,790 | $1,800 | Not Implemented |
LM0123 # 03 Y:2007 | 03 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,789 | $20,000 | Not Implemented |
LM0123 # 04 Y:2007 | 04 | 2007 | $37,630 | $1,000 | Not Implemented | |
LM0106 # 01 Y:2006 | 01 | 2006 | COVER OPEN TANKS | $3,315 | $1,500 | Implemented |
LM0106 # 02 Y:2006 | 02 | 2006 | $33,590 | $8,640 | Not Implemented | |
LM0081 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,802 | $0 | Not Implemented |
LM0081 # 02 Y:2004 | 02 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,857 | $300 | Implemented |
LM0081 # 03 Y:2004 | 03 | 2004 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $85 | $0 | Not Implemented |
LM0081 # 04 Y:2004 | 04 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $160 | $80 | Not Implemented |
LM0081 # 05 Y:2004 | 05 | 2004 | $233,065 | $1,000 | Not Implemented | |
LM0081 # 06 Y:2004 | 06 | 2004 | $292,248 | $4,925 | Not Implemented | |
LM0081 # 07 Y:2004 | 07 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,611 | $1,814 | Not Implemented |
SD0243 # 01 Y:2000 | 01 | 2000 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $17,132 | $28,575 | Not Implemented |
SD0243 # 02 Y:2000 | 02 | 2000 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $8,431 | $7,000 | Not Implemented |
SD0243 # 03 Y:2000 | 03 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,270 | $3,300 | Not Implemented |
SD0243 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,673 | $11,336 | Not Implemented |
SD0243 # 05 Y:2000 | 05 | 2000 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,209 | $7,872 | Implemented |
SD0243 # 06 Y:2000 | 06 | 2000 | INSULATE BARE EQUIPMENT | $4,293 | $9,936 | Implemented |
SD0243 # 07 Y:2000 | 07 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,087 | $0 | Not Implemented |
SD0243 # 08 Y:2000 | 08 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,753 | $1,300 | Not Implemented |
SD0243 # 09 Y:2000 | 09 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,098 | $500 | Implemented |
SD0243 # 10 Y:2000 | 10 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $953 | $2,425 | Not Implemented |