Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,112
matching recommendationsSIC | 3479 | Metal Coating And Allied Services |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NT0009 # 04 Y:2023 | 04 | 2023 | OPTIMIZE PLANT POWER FACTOR | $13,598 | $10,844 | Not Implemented |
NT0009 # 05 Y:2023 | 05 | 2023 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,796 | $18,600 | Not Implemented |
NT0009 # 06 Y:2023 | 06 | 2023 | PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT | $78,488 | $41,034 | Not Implemented |
MS0411 # 01 Y:2023 | 01 | 2023 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $16,956 | $42,807 | Not Implemented |
MS0411 # 02 Y:2023 | 02 | 2023 | INSTALL OCCUPANCY SENSORS | $113 | $335 | Not Implemented |
MS0411 # 03 Y:2023 | 03 | 2023 | USE SOLAR HEAT TO MAKE ELECTRICTY | $56,198 | $786,625 | Not Implemented |
MS0411 # 04 Y:2023 | 04 | 2023 | COVER CONTAINERS TO MINIMIZE EVAPORATIVE LOSSES | $4,180 | $4,512 | Not Implemented |
MS0411 # 05 Y:2023 | 05 | 2023 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $537 | $3,690 | Not Implemented |
SD0623 # 01 Y:2023 | 01 | 2023 | PREVENT EXCESSIVE SOLVENT USAGE (OPERATOR TRAINING) | $49,875 | $0 | Implemented |
SD0623 # 02 Y:2023 | 02 | 2023 | USE SOLAR HEAT TO MAKE ELECTRICTY | $43,378 | $245,406 | Not Implemented |
SD0623 # 03 Y:2023 | 03 | 2023 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $6,262 | $500 | Implemented |
SD0623 # 04 Y:2023 | 04 | 2023 | UPGRADE CONTROLS ON COMPRESSORS | $2,157 | $6,534 | Not Implemented |
SD0623 # 05 Y:2023 | 05 | 2023 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,218 | $7,000 | Not Implemented |
SU0526 # 01 Y:2022 | 01 | 2022 | DISCONNECT BALLASTS | $4,882 | $0 | Not Implemented |
SU0526 # 02 Y:2022 | 02 | 2022 | PAY BILLS ON TIME TO AVOID LATE FEES | $1,969 | $0 | Not Implemented |
SU0526 # 03 Y:2022 | 03 | 2022 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,491 | $52 | Not Implemented |
SU0526 # 04 Y:2022 | 04 | 2022 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,343 | $792 | Not Implemented |
SU0526 # 05 Y:2022 | 05 | 2022 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,823 | $447 | Not Implemented |
SU0526 # 06 Y:2022 | 06 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $433 | $284 | Not Implemented |
SU0526 # 07 Y:2022 | 07 | 2022 | INSTALL SET-BACK TIMERS | $423 | $627 | Not Implemented |
SU0526 # 08 Y:2022 | 08 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $158,273 | $259,521 | Not Implemented |
SU0526 # 09 Y:2022 | 09 | 2022 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $9,454 | $16,991 | Not Implemented |
SU0526 # 10 Y:2022 | 10 | 2022 | RECOVER WASTE HEAT FROM EQUIPMENT | $98 | $369 | Not Implemented |
UW2208 # 01 Y:2022 | 01 | 2022 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $643 | $0 | Implemented |
UW2208 # 02 Y:2022 | 02 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $954 | $2,680 | Implemented |