IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,321

matching recommendations
Reset
SIC 349 Misc. Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TT0079 # 02 Y:2011 02 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $336 $0 Implemented
TT0079 # 03 Y:2011 03 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $205 $0 Implemented
TT0079 # 06 Y:2011 06 2011 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $1,937 $0 Implemented
IA0466 # 01 Y:2011 01 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,117 $500 Implemented
IA0466 # 02 Y:2011 02 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $159 $310 Implemented
IA0466 # 04 Y:2011 04 2011 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $199 $35 Implemented
IA0466 # 05 Y:2011 05 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,338 $6,607 Implemented
IA0466 # 06 Y:2011 06 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,604 $11,597 Implemented
IA0466 # 07 Y:2011 07 2011 INSTALL OCCUPANCY SENSORS $343 $308 Implemented
IA0466 # 09 Y:2011 09 2011 IMPROVE COMBUSTION CONTROL CAPABILITY $482 $480 Implemented
UD0841 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $88,915 $80,000 Implemented
UD0841 # 03 Y:2011 03 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $50,283 $40,000 Implemented
UD0841 # 04 Y:2011 04 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,101 $30,000 Implemented
UD0841 # 05 Y:2011 05 2011 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $43,664 $0 Implemented
UD0841 # 06 Y:2011 06 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $29,362 $500 Implemented
UD0841 # 10 Y:2011 10 2011 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $42,803 $110,624 Implemented
UD0841 # 13 Y:2011 13 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $417 $1,012 Implemented
UD0841 # 14 Y:2011 14 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $64,796 $20,000 Implemented
UD0841 # 15 Y:2011 15 2011 ISOLATE HOT OR COLD EQUIPMENT $33,356 $2,000 Implemented
UD0841 # 17 Y:2011 17 2011 INSTALL AUTOMATIC STACK DAMPER $20,941 $600 Implemented
UD0841 # 18 Y:2011 18 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $2,133 $2,098 Implemented
BD0395 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,465 $34,827 Implemented
BD0395 # 03 Y:2011 03 2011 INSTALL OCCUPANCY SENSORS $1,621 $825 Implemented
BD0395 # 06 Y:2011 06 2011 USE PHOTOCELL CONTROLS $615 $375 Implemented
NC0426 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $815 $1,530 Implemented