Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
171
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0714 # 08 Y:2005 | 08 | 2005 | USE MINIMUM SAFE OVEN VENTILATION | $1,972 | $150 | Implemented |
UD0714 # 09 Y:2005 | 09 | 2005 | MINIMIZE WATER USAGE | $1,311 | $1,200 | Implemented |
UD0714 # 10 Y:2005 | 10 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,296 | $0 | Implemented |
UD0714 # 11 Y:2005 | 11 | 2005 | MINIMIZE WATER USAGE | $1,138 | $350 | Implemented |
UD0714 # 15 Y:2005 | 15 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $884 | $0 | Implemented |
WV0307 # 03 Y:2004 | 03 | 2004 | ISOLATE HOT OR COLD EQUIPMENT | $3,113 | $755 | Implemented |
WV0307 # 08 Y:2004 | 08 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,767 | $53 | Implemented |
WV0307 # 09 Y:2004 | 09 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,177 | $210 | Implemented |
WV0307 # 10 Y:2004 | 10 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $1,513 | $271 | Implemented |
WV0307 # 11 Y:2004 | 11 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $903 | $0 | Implemented |
WV0307 # 12 Y:2004 | 12 | 2004 | USE OPTIMUM THICKNESS INSULATION | $278 | $380 | Implemented |
WV0307 # 13 Y:2004 | 13 | 2004 | INSULATE BARE EQUIPMENT | $262 | $260 | Implemented |
WV0307 # 14 Y:2004 | 14 | 2004 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,224 | $140 | Implemented |
WV0286 # 02 Y:2004 | 02 | 2004 | OPTIMIZE PLANT POWER FACTOR | $4,469 | $3,580 | Implemented |
WV0286 # 03 Y:2004 | 03 | 2004 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,072 | $360 | Implemented |
WV0286 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,971 | $250 | Implemented |
WV0286 # 05 Y:2004 | 05 | 2004 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,455 | $1,770 | Implemented |
WV0286 # 06 Y:2004 | 06 | 2004 | INSULATE BARE EQUIPMENT | $1,353 | $251 | Implemented |
WV0286 # 09 Y:2004 | 09 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $830 | $0 | Implemented |
WV0286 # 10 Y:2004 | 10 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $828 | $283 | Implemented |
WV0286 # 11 Y:2004 | 11 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $743 | $1,100 | Implemented |
WV0286 # 12 Y:2004 | 12 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $318 | $250 | Implemented |
UD0688 # 02 Y:2004 | 02 | 2004 | USE OPTIMUM TEMPERATURE | $143,925 | $500,000 | Implemented |
UD0688 # 03 Y:2004 | 03 | 2004 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $31,450 | $7,250 | Implemented |
UD0688 # 05 Y:2004 | 05 | 2004 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $12,457 | $31,250 | Implemented |