Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,115
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0216 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,265 | $875 | Not Implemented |
LL0216 # 07 Y:2005 | 07 | 2005 | COMBINE UTILITY METERS | $1,025 | $720 | Implemented |
LL0216 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $290 | $300 | Not Implemented |
LL0216 # 09 Y:2005 | 09 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,445 | $0 | Implemented |
LL0216 # 10 Y:2005 | 10 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $13,500 | $2,170 | Not Implemented |
LL0216 # 11 Y:2005 | 11 | 2005 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $12,630 | $18,780 | Not Implemented |
LL0216 # 12 Y:2005 | 12 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,040 | $2,303 | Implemented |
MS0267 # 01 Y:2005 | 01 | 2005 | OPTIMIZE PLANT POWER FACTOR | $30,643 | $45,270 | Implemented |
MS0267 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,354 | $141,305 | Implemented |
MS0267 # 03 Y:2005 | 03 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $1,157 | $2,124 | Not Implemented |
MS0267 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $750 | $228 | Implemented |
MS0267 # 05 Y:2005 | 05 | 2005 | AIR CONDITION ONLY SPACE NECESSARY | $613 | $240 | Not Implemented |
MS0267 # 06 Y:2005 | 06 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $128 | $0 | Not Implemented |
MA0568 # 01 Y:2005 | 01 | 2005 | ADOPT IN-HOUSE MATERIAL GENERATION | $174,960 | $252,000 | Not Implemented |
MA0568 # 02 Y:2005 | 02 | 2005 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $20,082 | $7,750 | Implemented |
MA0568 # 03 Y:2005 | 03 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $10,788 | $12,000 | Implemented |
MA0568 # 04 Y:2005 | 04 | 2005 | OPTIMIZE PLANT POWER FACTOR | $5,122 | $6,750 | Implemented |
MA0568 # 05 Y:2005 | 05 | 2005 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $4,092 | $6,000 | Implemented |
MA0568 # 06 Y:2005 | 06 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,459 | $2,888 | Not Implemented |
LM0088 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,003 | $300 | Not Implemented |
LM0088 # 02 Y:2005 | 02 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $991 | $250 | Not Implemented |
LM0088 # 03 Y:2005 | 03 | 2005 | USE EVAPORATION TO CONCENTRATE MATERIAL | $7,975 | $3,000 | Implemented |
LM0088 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,349 | $0 | Not Implemented |
LM0088 # 05 Y:2005 | 05 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $82 | $126 | Not Implemented |
LM0087 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,069 | $17,418 | Implemented |