Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
35
matching recommendationsSIC | 3492 | Fluid Power Valves & Hose Fittings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0401 # 04 Y:2022 | 04 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,273 | $1,930 | Implemented |
MI0401 # 03 Y:2022 | 03 | 2022 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $7,485 | $25,433 | Implemented |
MI0401 # 01 Y:2022 | 01 | 2022 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $15,026 | $580 | Implemented |
MI0399 # 07 Y:2021 | 07 | 2021 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,286 | $4,468 | Implemented |
MI0399 # 02 Y:2021 | 02 | 2021 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $54,060 | $240,000 | Implemented |
MI0399 # 03 Y:2021 | 03 | 2021 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $21,020 | $320 | Implemented |
MI0399 # 04 Y:2021 | 04 | 2021 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $15,245 | $70,400 | Implemented |
MI0399 # 05 Y:2021 | 05 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,405 | $1,670 | Implemented |
MI0286 # 01 Y:2015 | 01 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $19,094 | $29,862 | Implemented |
MI0286 # 02 Y:2015 | 02 | 2015 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $14,710 | $100,350 | Implemented |
MI0285 # 02 Y:2015 | 02 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $22,640 | $52,920 | Implemented |
MI0285 # 03 Y:2015 | 03 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $15,400 | $80 | Implemented |
MI0285 # 04 Y:2015 | 04 | 2015 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $13,892 | $76,650 | Implemented |
MI0284 # 02 Y:2015 | 02 | 2015 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $28,449 | $55,650 | Implemented |
MI0284 # 04 Y:2015 | 04 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $11,198 | $6,520 | Implemented |
MI0284 # 03 Y:2015 | 03 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $28,415 | $160 | Implemented |
MI0284 # 01 Y:2015 | 01 | 2015 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $77,529 | $180,000 | Implemented |
MI0284 # 07 Y:2015 | 07 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $1,588 | $2,527 | Implemented |
UF0373 # 09 Y:2006 | 09 | 2006 | IMPROVE SPACE COMFORT CONDITIONING | $26,438 | $1,500 | Implemented |
UF0373 # 08 Y:2006 | 08 | 2006 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $2,448 | $954 | Implemented |
UF0373 # 05 Y:2006 | 05 | 2006 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $15,306 | $1,300 | Implemented |
UF0373 # 04 Y:2006 | 04 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,178 | $1,272 | Implemented |
UF0373 # 03 Y:2006 | 03 | 2006 | INSTALL OCCUPANCY SENSORS | $13,109 | $1,327 | Implemented |
UF0373 # 02 Y:2006 | 02 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,366 | $0 | Implemented |
UF0373 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,471 | $1,124 | Implemented |