Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
160
matching recommendationsSIC | 3495 | Wire Springs |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0466 # 03 Y:2011 | 03 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $224 | $25 | Not Implemented |
IA0466 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,338 | $6,607 | Implemented |
IA0466 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,604 | $11,597 | Implemented |
IA0466 # 07 Y:2011 | 07 | 2011 | INSTALL OCCUPANCY SENSORS | $343 | $308 | Implemented |
IA0466 # 08 Y:2011 | 08 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $8,615 | $16,800 | Not Implemented |
IA0466 # 09 Y:2011 | 09 | 2011 | IMPROVE COMBUSTION CONTROL CAPABILITY | $482 | $480 | Implemented |
AM0599 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,590 | $24,740 | Implemented |
AM0599 # 03 Y:2011 | 03 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,240 | $13 | Implemented |
AM0599 # 01 Y:2011 | 01 | 2011 | OPTIMIZE PLANT POWER FACTOR | $17,840 | $28,410 | Implemented |
AM0599 # 04 Y:2011 | 04 | 2011 | INSTALL SKYLIGHTS | $5,535 | $0 | Implemented |
AM0599 # 05 Y:2011 | 05 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,810 | $500 | Implemented |
AM0599 # 06 Y:2011 | 06 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,270 | $8,410 | Not Implemented |
AM0599 # 07 Y:2011 | 07 | 2011 | USE SYNTHETIC LUBRICANT | $790 | $0 | Not Implemented |
AM0599 # 08 Y:2011 | 08 | 2011 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $530 | $325 | Not Implemented |
AM0599 # 09 Y:2011 | 09 | 2011 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $490 | $200 | Not Implemented |
AM0599 # 10 Y:2011 | 10 | 2011 | OPTIMIZE PLANT POWER FACTOR | $415 | $1,270 | Implemented |
IC0107 # 05 Y:2005 | 05 | 2005 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $13,232 | $0 | Not Implemented |
IC0107 # 01 Y:2005 | 01 | 2005 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $9,504 | $19,598 | Not Implemented |
IC0107 # 02 Y:2005 | 02 | 2005 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $93,103 | $4,926 | Not Implemented |
IC0107 # 03 Y:2005 | 03 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,772 | $39,896 | Not Implemented |
IC0107 # 04 Y:2005 | 04 | 2005 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $19,487 | $61,560 | Not Implemented |
IC0107 # 06 Y:2005 | 06 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $22,485 | $224,000 | Not Implemented |
IC0107 # 12 Y:2005 | 12 | 2005 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $3,508 | $608 | Not Implemented |
IC0107 # 10 Y:2005 | 10 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,309 | $0 | Not Implemented |
IC0107 # 11 Y:2005 | 11 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,097 | $9,021 | Not Implemented |