Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
27
matching recommendationsSIC | 3496 | Misc. Fabricated Wire Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0581 # 09 Y:2019 | 09 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $938 | $0 | Implemented |
WV0581 # 08 Y:2019 | 08 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,540 | $100 | Implemented |
WV0581 # 07 Y:2019 | 07 | 2019 | DEVELOP A REPAIR/REPLACE POLICY | $4,849 | $738 | Implemented |
WV0581 # 06 Y:2019 | 06 | 2019 | RECYCLE WHITE WATER | $8,651 | $4,100 | Implemented |
WV0581 # 05 Y:2019 | 05 | 2019 | UPGRADE CONTROLS ON COMPRESSORS | $9,387 | $4,000 | Implemented |
WV0581 # 04 Y:2019 | 04 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,233 | $58,107 | Implemented |
WV0581 # 03 Y:2019 | 03 | 2019 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $28,868 | $78,000 | Implemented |
LE0381 # 10 Y:2014 | 10 | 2014 | INSTALL OCCUPANCY SENSORS | $6,567 | $9,190 | Implemented |
LE0381 # 06 Y:2014 | 06 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,665 | $3,500 | Implemented |
LE0381 # 05 Y:2014 | 05 | 2014 | REPAIR AND ELIMINATE STEAM LEAKS | $3,233 | $771 | Implemented |
LE0381 # 01 Y:2014 | 01 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $1,880 | $36 | Implemented |
DL0061 # 05 Y:2010 | 05 | 2010 | ADD AREA LIGHTING SWITCHES | $23,365 | $120 | Implemented |
DL0061 # 06 Y:2010 | 06 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $414 | $440 | Implemented |
DL0061 # 03 Y:2010 | 03 | 2010 | DISCONNECT BALLASTS | $655 | $5,000 | Implemented |
DL0061 # 10 Y:2010 | 10 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,529 | $47,000 | Implemented |
DL0061 # 14 Y:2010 | 14 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,396 | $20,804 | Implemented |
WV0406 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,098 | $49,200 | Implemented |
WV0398 # 15 Y:2009 | 15 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,030 | $0 | Implemented |
WV0398 # 11 Y:2009 | 11 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,235 | $419 | Implemented |
WV0398 # 09 Y:2009 | 09 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,891 | $900 | Implemented |
WV0398 # 08 Y:2009 | 08 | 2009 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $10,882 | $1,000 | Implemented |
WV0398 # 07 Y:2009 | 07 | 2009 | DEVELOP A REPAIR/REPLACE POLICY | $11,204 | $793 | Implemented |
LE0212 # 07 Y:2005 | 07 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,111 | $1,500 | Implemented |
LE0212 # 06 Y:2005 | 06 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $6,490 | $1,925 | Implemented |
LE0212 # 02 Y:2005 | 02 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $38,827 | $28,400 | Implemented |