Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

238

matching recommendations
Reset
SIC 3498 Fabricated Pipe And Fittings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0577 # 02 Y:2010 02 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,500 $9,155 Implemented
AM0577 # 03 Y:2010 03 2010 OPTIMIZE PLANT POWER FACTOR $6,410 $21,100 Implemented
AM0577 # 05 Y:2010 05 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,980 $17 Implemented
AM0577 # 06 Y:2010 06 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,660 $300 Implemented
AM0577 # 11 Y:2010 11 2010 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $310 $190 Implemented
AM0577 # 12 Y:2010 12 2010 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $270 $0 Implemented
LL0328 # 03 Y:2010 03 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,572 $2,800 Implemented
LL0328 # 02 Y:2010 02 2010 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $9,654 $3,600 Implemented
LL0328 # 01 Y:2010 01 2010 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN $26,498 $304 Implemented
LL0327 # 02 Y:2010 02 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,725 $30 Implemented
LL0327 # 01 Y:2010 01 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,425 $4,180 Implemented
AM0533 # 01 Y:2007 01 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $98,110 $155,442 Implemented
AM0533 # 02 Y:2007 02 2007 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $163,900 $0 Implemented
AM0533 # 03 Y:2007 03 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,600 $700 Implemented
AM0533 # 04 Y:2007 04 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,395 $1,350 Implemented
AM0533 # 06 Y:2007 06 2007 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,750 $0 Implemented
AM0533 # 08 Y:2007 08 2007 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $475 $65 Implemented
LL0216 # 05 Y:2005 05 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,613 $840 Implemented
LL0216 # 12 Y:2005 12 2005 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $2,040 $2,303 Implemented
LL0216 # 09 Y:2005 09 2005 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $1,445 $0 Implemented
LL0216 # 07 Y:2005 07 2005 COMBINE UTILITY METERS $1,025 $720 Implemented
LL0216 # 04 Y:2005 04 2005 USE PHOTOCELL CONTROLS $5,264 $420 Implemented
LL0216 # 02 Y:2005 02 2005 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $22,512 $1,410 Implemented
OK0686 # 03 Y:2004 03 2004 INSTALL OCCUPANCY SENSORS $3,350 $1,136 Implemented
OK0686 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,153 $36,618 Implemented