Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
238
matching recommendationsSIC | 3498 | Fabricated Pipe And Fittings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0271 # 09 Y:1997 | 09 | 1997 | USE MORE EFFICIENT ADHESIVE APPLICATORS | $381 | $360 | Implemented |
OK0509 # 01 Y:1996 | 01 | 1996 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $1,243 | $0 | Implemented |
OK0509 # 02 Y:1996 | 02 | 1996 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $14,966 | $18,000 | Implemented |
OK0509 # 04 Y:1996 | 04 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,419 | $855 | Implemented |
OK0509 # 05 Y:1996 | 05 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $470 | $460 | Implemented |
OK0509 # 06 Y:1996 | 06 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $538 | $248 | Implemented |
UM0068 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $994 | $1,630 | Implemented |
UM0068 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,473 | $18,075 | Implemented |
UM0068 # 03 Y:1996 | 03 | 1996 | OPTIMIZE PLANT POWER FACTOR | $5,202 | $5,124 | Implemented |
UM0068 # 06 Y:1996 | 06 | 1996 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $24,612 | $3,100 | Implemented |
BD0065 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $12,474 | $26,320 | Implemented |
BD0065 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,584 | $8,600 | Implemented |
BD0065 # 04 Y:1996 | 04 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $753 | $946 | Implemented |
BD0065 # 07 Y:1996 | 07 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $11,153 | $7,500 | Implemented |
BD0065 # 08 Y:1996 | 08 | 1996 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $8,611 | $1,395 | Implemented |
BD0035 # 01 Y:1995 | 01 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $19,345 | $11,900 | Implemented |
BD0035 # 04 Y:1995 | 04 | 1995 | INSTALL OCCUPANCY SENSORS | $362 | $300 | Implemented |
AR0062 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $997 | $380 | Implemented |
AR0062 # 02 Y:1995 | 02 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $14,786 | $900 | Implemented |
AR0062 # 03 Y:1995 | 03 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,829 | $0 | Implemented |
AR0062 # 04 Y:1995 | 04 | 1995 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $490 | $1,000 | Implemented |
AR0062 # 05 Y:1995 | 05 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,615 | $300 | Implemented |
AR0062 # 06 Y:1995 | 06 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,364 | $400 | Implemented |
AR0062 # 07 Y:1995 | 07 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $8,172 | $16,900 | Implemented |
AR0062 # 09 Y:1995 | 09 | 1995 | REPAIR OR REPLACE STEAM TRAPS | $420 | $100 | Implemented |