Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
238
matching recommendationsSIC | 3498 | Fabricated Pipe And Fittings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AR0062 # 10 Y:1995 | 10 | 1995 | MINIMIZE WATER USAGE | $1,143 | $100 | Implemented |
BD0031 # 02 Y:1995 | 02 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,068 | $420 | Implemented |
BD0031 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $234 | $346 | Implemented |
BD0031 # 05 Y:1995 | 05 | 1995 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $87 | $20 | Implemented |
BD0031 # 08 Y:1995 | 08 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,569 | $600 | Implemented |
TN0512 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,901 | $840 | Implemented |
GT0496 # 01 Y:1993 | 01 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,890 | $750 | Implemented |
MO0054 # 07 Y:1992 | 07 | 1992 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $192 | $620 | Implemented |
AM0105 # 02 Y:1990 | 02 | 1990 | OPTIMIZE PLANT POWER FACTOR | $7,790 | $21,500 | Implemented |
AM0105 # 03 Y:1990 | 03 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,600 | $500 | Implemented |
AM0105 # 04 Y:1990 | 04 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $4,000 | $0 | Implemented |
AM0105 # 06 Y:1990 | 06 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,800 | $400 | Implemented |
AM0105 # 08 Y:1990 | 08 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $180 | $170 | Implemented |
CO0189 # 02 Y:1990 | 02 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,716 | $15,000 | Implemented |
CO0189 # 03 Y:1990 | 03 | 1990 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $800 | $1,720 | Implemented |
CO0189 # 04 Y:1990 | 04 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,170 | $200 | Implemented |
CO0189 # 05 Y:1990 | 05 | 1990 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,100 | $3,200 | Implemented |
CO0189 # 06 Y:1990 | 06 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $800 | $500 | Implemented |
CO0189 # 07 Y:1990 | 07 | 1990 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $230 | $300 | Implemented |
AM0077 # 01 Y:1990 | 01 | 1990 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,200 | $51,900 | Implemented |
AM0077 # 02 Y:1990 | 02 | 1990 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $10,385 | $12,000 | Implemented |
AM0077 # 03 Y:1990 | 03 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,660 | $1,500 | Implemented |
AM0077 # 04 Y:1990 | 04 | 1990 | INSTALL SET-BACK TIMERS | $910 | $0 | Implemented |
AM0077 # 05 Y:1990 | 05 | 1990 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $440 | $0 | Implemented |
AM0077 # 06 Y:1990 | 06 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $34 | $31 | Implemented |