Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
28
matching recommendationsSIC | 3499 | Fabricated Metal Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0143 # 04 Y:2019 | 04 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,884 | $4,500 | Implemented |
WM0053 # 12 Y:2014 | 12 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,677 | $19,918 | Implemented |
WM0053 # 10 Y:2014 | 10 | 2014 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,892 | $0 | Implemented |
WM0053 # 02 Y:2014 | 02 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $17,731 | $1,292 | Implemented |
WM0053 # 13 Y:2014 | 13 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $560 | $512 | Implemented |
WM0038 # 09 Y:2014 | 09 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $149 | $460 | Implemented |
WM0038 # 05 Y:2014 | 05 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $637 | $1,519 | Implemented |
WM0038 # 04 Y:2014 | 04 | 2014 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $622 | $500 | Implemented |
WM0038 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,678 | $1,768 | Implemented |
WM0038 # 02 Y:2014 | 02 | 2014 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $172 | $73 | Implemented |
WM0038 # 01 Y:2014 | 01 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,700 | $16,042 | Implemented |
IC0090 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,918 | $300 | Implemented |
IC0090 # 05 Y:2004 | 05 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $559 | $77 | Implemented |
IC0090 # 04 Y:2004 | 04 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,643 | $9,400 | Implemented |
IC0090 # 01 Y:2004 | 01 | 2004 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $17,317 | $0 | Implemented |
WI0441 # 02 Y:2003 | 02 | 2003 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $5,650 | $16,800 | Implemented |
WI0441 # 03 Y:2003 | 03 | 2003 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $2,550 | $0 | Implemented |
WI0406 # 01 Y:2001 | 01 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $8,841 | $0 | Implemented |
WI0222 # 04 Y:1994 | 04 | 1994 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,038 | $850 | Implemented |
WI0222 # 06 Y:1994 | 06 | 1994 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $444 | $0 | Implemented |
WI0222 # 02 Y:1994 | 02 | 1994 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $1,553 | $1,500 | Implemented |
WI0054 # 05 Y:1989 | 05 | 1989 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,752 | $4,500 | Implemented |
WI0054 # 04 Y:1989 | 04 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,279 | $6,300 | Implemented |
WI0054 # 03 Y:1989 | 03 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $985 | $500 | Implemented |
WI0054 # 02 Y:1989 | 02 | 1989 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $91,315 | $20,000 | Implemented |