Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,117
matching recommendationsSIC | 3499 | Fabricated Metal Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0101 # 01 Y:2001 | 01 | 2001 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $9,696 | $500 | Implemented |
LE0101 # 02 Y:2001 | 02 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $26,225 | $30,000 | Implemented |
LE0101 # 03 Y:2001 | 03 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $78,362 | $2,500 | Implemented |
LE0101 # 04 Y:2001 | 04 | 2001 | IMPROVE LUBRICATION PRACTICES | $3,752 | $800 | Implemented |
LE0101 # 05 Y:2001 | 05 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $89,879 | $0 | Implemented |
LE0101 # 06 Y:2001 | 06 | 2001 | CLOSE OFF UNNEEDED STEAM LINES | $3,984 | $2,000 | Implemented |
LE0101 # 07 Y:2001 | 07 | 2001 | USE OPTIMUM THICKNESS INSULATION | $5,167 | $2,000 | Implemented |
LL0101 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $646 | $854 | Not Implemented |
LL0101 # 02 Y:2001 | 02 | 2001 | OPTIMIZE PLANT POWER FACTOR | $478 | $1,200 | Not Implemented |
LL0101 # 03 Y:2001 | 03 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,840 | $6,234 | Not Implemented |
LL0101 # 04 Y:2001 | 04 | 2001 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $153 | $268 | Implemented |
LL0101 # 05 Y:2001 | 05 | 2001 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $248 | $424 | Implemented |
LL0101 # 06 Y:2001 | 06 | 2001 | REDUCE SCRAP PRODUCTION | $1,788 | $0 | Implemented |
ND0364 # 01 Y:2000 | 01 | 2000 | DEVELOP A REPAIR/REPLACE POLICY | $8,340 | $22,377 | Implemented |
ND0364 # 02 Y:2000 | 02 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,206 | $0 | Implemented |
ND0364 # 03 Y:2000 | 03 | 2000 | INSTALL OCCUPANCY SENSORS | $839 | $600 | Not Implemented |
ND0364 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $271 | $575 | Implemented |
ND0364 # 05 Y:2000 | 05 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,221 | $1,000 | Not Implemented |
ND0364 # 06 Y:2000 | 06 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $75 | $200 | Implemented |
ND0364 # 07 Y:2000 | 07 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $605 | $400 | Not Implemented |
ND0364 # 08 Y:2000 | 08 | 2000 | MINIMIZE WATER USAGE | $821 | $2,875 | Not Implemented |
MA0470 # 01 Y:2000 | 01 | 2000 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,970 | $500 | Implemented |
MA0470 # 02 Y:2000 | 02 | 2000 | USE RADIANT HEATER FOR SPOT HEATING | $3,064 | $12,000 | Not Implemented |
MA0470 # 03 Y:2000 | 03 | 2000 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,099 | $4,500 | Not Implemented |
MA0470 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,495 | $365 | Implemented |