Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15,451
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0320 # 03 Y:2002 | 03 | 2002 | REDUCE VENTILATION AIR | $2,184 | $1,320 | n/a |
AS0320 # 04 Y:2002 | 04 | 2002 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,123 | $7,350 | n/a |
AS0320 # 05 Y:2002 | 05 | 2002 | USE SYNTHETIC LUBRICANT | $645 | $465 | n/a |
AS0320 # 06 Y:2002 | 06 | 2002 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $4,380 | $60 | n/a |
AS0320 # 07 Y:2002 | 07 | 2002 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,932 | $60 | n/a |
AS0320 # 08 Y:2002 | 08 | 2002 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $17,971 | $374 | n/a |
OK0636 # 01 Y:2002 | 01 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,565 | $16,300 | Implemented |
OK0636 # 02 Y:2002 | 02 | 2002 | COVER OPEN TANKS | $2,412 | $528 | Not Implemented |
OK0636 # 03 Y:2002 | 03 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,525 | $1,500 | Not Implemented |
OK0636 # 04 Y:2002 | 04 | 2002 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $175,200 | $12,800 | Implemented |
OK0636 # 05 Y:2002 | 05 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,410 | $1,400 | Implemented |
OK0636 # 06 Y:2002 | 06 | 2002 | BURN WOOD BY-PRODUCTS FOR HEAT | $15,400 | $22,800 | Not Implemented |
WI0417 # 01 Y:2002 | 01 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,160 | $2,000 | Implemented |
WI0417 # 02 Y:2002 | 02 | 2002 | TREAT AND REUSE RINSE WATERS | $7,660 | $8,000 | Implemented |
WI0417 # 03 Y:2002 | 03 | 2002 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $4,700 | $0 | Not Implemented |
WI0417 # 04 Y:2002 | 04 | 2002 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,600 | $1,100 | Not Implemented |
WI0417 # 05 Y:2002 | 05 | 2002 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,453 | $1,560 | Not Implemented |
WI0417 # 06 Y:2002 | 06 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,606 | $339 | Implemented |
WI0417 # 07 Y:2002 | 07 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,318 | $740 | Implemented |
WI0417 # 08 Y:2002 | 08 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $923 | $1,647 | Implemented |
UD0642 # 01 Y:2002 | 01 | 2002 | DEVELOP STANDARD OPERATING PROCEDURES | $39,312 | $0 | Not Implemented |
UD0642 # 02 Y:2002 | 02 | 2002 | INSTALL SKYLIGHTS | $8,274 | $39,600 | Not Implemented |
UD0642 # 03 Y:2002 | 03 | 2002 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,876 | $5,000 | Not Implemented |
UD0642 # 04 Y:2002 | 04 | 2002 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,364 | $7,000 | Implemented |
UD0642 # 05 Y:2002 | 05 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,027 | $1,450 | Implemented |