Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15,543
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0290 # 04 Y:1989 | 04 | 1989 | KEEP LAMPS AND REFLECTORS CLEAN | $6,394 | $11,600 | Implemented |
UD0290 # 05 Y:1989 | 05 | 1989 | REDUCE GLAZED AREAS IN BUILDINGS | $22,077 | $21,750 | Implemented |
UD0290 # 06 Y:1989 | 06 | 1989 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,146 | $465 | Implemented |
CO0149 # 01 Y:1989 | 01 | 1989 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,830 | $1,200 | Implemented |
CO0149 # 02 Y:1989 | 02 | 1989 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,014 | $400 | Implemented |
CO0149 # 03 Y:1989 | 03 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $330 | $500 | Implemented |
CO0149 # 04 Y:1989 | 04 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $430 | $200 | Implemented |
CO0149 # 05 Y:1989 | 05 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $3,260 | $1,000 | Implemented |
CO0149 # 06 Y:1989 | 06 | 1989 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,325 | $100 | Implemented |
CO0149 # 07 Y:1989 | 07 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $417 | $900 | Implemented |
CO0149 # 08 Y:1989 | 08 | 1989 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $840 | $300 | Implemented |
MA0151 # 01 Y:1989 | 01 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,228 | $426 | Not Implemented |
MA0151 # 02 Y:1989 | 02 | 1989 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $1,218 | $305 | Not Implemented |
MA0151 # 03 Y:1989 | 03 | 1989 | RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS | $4,308 | $243 | Not Implemented |
MA0151 # 04 Y:1989 | 04 | 1989 | BURN A LESS EXPENSIVE GRADE OF FUEL | $12,509 | $15,150 | Implemented |
MA0151 # 05 Y:1989 | 05 | 1989 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,022 | $593 | Implemented |
MA0151 # 06 Y:1989 | 06 | 1989 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $1,093 | $592 | Not Implemented |
MA0151 # 07 Y:1989 | 07 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,050 | $3,150 | Not Implemented |
AM0065 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,893 | $418 | Implemented |
AM0065 # 02 Y:1989 | 02 | 1989 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $4,000 | $4,000 | Not Implemented |
AM0065 # 03 Y:1989 | 03 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $3,675 | $13,500 | Not Implemented |
AM0065 # 04 Y:1989 | 04 | 1989 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,540 | $6,475 | Not Implemented |
AM0065 # 05 Y:1989 | 05 | 1989 | REDUCE VENTILATION AIR | $778 | $1,950 | Not Implemented |
AM0065 # 06 Y:1989 | 06 | 1989 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $640 | $2,750 | Not Implemented |
UD0291 # 01 Y:1989 | 01 | 1989 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,548 | $6,000 | Not Implemented |